Table 2.19 Power Supply and Alarm Display
Main Circuit Power Supply
External 24 V Power Supply
o2-23
[External 24V Powerloss
Detection]
o2-26
[Alarm Display at Ext. 24V
Power]
Alarm Display
ON
ON
-
-
-
ON
OFF
0 [Disabled]
-
-
1 [Enabled]
-
L24v [Loss of External Power 24
Supply]
OFF
ON
-
0 [Disabled]
“
Ready
”
LED light flashes
quickly
-
1 [Enabled]
EP24v [External Power 24V
Supply]
Operation When Using External 24 V Power Supply
To operate the drive, de-energize the main circuit power supply and connect an external 24 V power supply to
terminals PS-AC.
Function
Operation
Solution
Keypad
The keypad operates the same as when the main circuit power supply
is ON. The drive will not detect
oPr [Keypad Connection Fault]
.
-
Data Log
The data log function operates the same as when the main circuit
power supply is ON.
The operation is different for different drive software versions.
-
Communications by Communication Option
or MEMOBUS/Modbus Communication
Terminals
Communication operates the same as when the main circuit power
supply is ON.
-
MFAI
MFAI operates the same as when the main circuit power supply is
ON.
-
MFAO
MFAO operates the same as when the main circuit power supply is
ON.
-
MFDI
MFDI does not operate when the main circuit power supply of the
drive is OFF.
Connect the external 24 V power supply to the MFDI
selection common terminal (SC).
MFDO
Multi-Function Photocoupler Output
Fault Relay Output Terminal
MFDO operates the same as when the main circuit power supply is
ON.
The operations of MFDO terminals and fault relay output terminals
set for
H2-xx = E, 10E [Fault]
are different for different drive
software versions.
-
Encoder Option Speed Detection (PG-B3,
PG-X3, PG-RT3)
Encoder options do not operate when the main circuit power supply of
the drive is OFF.
The operation to detect encoder option-related faults is different for
different software versions.
When you use an encoder, make sure that the drive main
circuit power supply is ON.
Analog Input Option (AI-A3)
Analog input options operate the same as when the main circuit power
supply is ON.
-
Analog Output Option (AO-A3)
Analog output options operate the same as when the main circuit
power supply is ON.
The operation is different for different drive software versions.
-
Digital Input Option (DI-A3)
Digital input options do not operate when the main circuit power
supply of the drive is OFF.
Connect the external 24 V power supply to the Input
signal common terminal (SC).
Digital Output Option (DO-A3)
Digital output options operate the same as when the main circuit
power supply is ON.
-
*1
When you use an external 24 V power supply, the operation of the data log function is different for different drive software versions.
On drives with software versions PRG: 01021 and later, you can continue the data log function.
Note:
The
“
PRG
”
column on the nameplate on the right side of the drive identifies the software version. You can also use
U1-25
[SoftwareNumber FLASH]
to identify the software version.
*2
When you use MFDI and a Digital Input option (DI-A3), wire the terminals as shown in
Wiring MFDI Terminals on page 105
or
Wiring Digital Input Option (DI-A3) on page 105
.
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...