EZZ023534<1>
18 / 21
H1 Multi-Function Digital Inputs
Setting
Value
Setting Value
Setting Value
52
Wire Length
Correction 2
V/f CL-V/f OLV CLV AOLV
Corrects the center of gravity position of the wire tip using an external digital
input.
When S9-14=0 [Wire Length Detection Method = Fix], the setting value of
S9-19 [Wire Length] is corrected with the setting value of S9-29 [Correction
value2 of Wire Length].
When S9-14=2 or 2 [Wire Length Detection Method = External], the wire
length calculated from the external input is corrected with the setting value of
S9-29 [Correction value1 of Wire Length].
The correction value is the total value of the correction values that are
enabled by Wire Length Correction 1 to 3.
14
53
Wire Length
Correction 3
V/f CL-V/f OLV CLV AOLV
Corrects the center of gravity position of the wire tip using an external digital
input.
When S9-14 = 0 [Wire Length Detection Method = Fix], the setting value of
S9-19 [Wire Length] is corrected with the setting value of S9-30 [Correction
value3 of Wire Length].
When S9-14 = 1 or 2 [Wire Length Detection Method = External], the wire
length calculated from the external input is corrected with the setting value of
S9-30.
The correction value is the total value of the correction values that are
enabled by Wire Length Correction 1 to 3.
14
13C
Home Position Set
Inverse Output
V/f
CL-V/f OLV CLV AOLV
Inverse output of setting value 3C.
-
150
Anti Swing Switch
Inverse Input
V/f CL-V/f OLV CLV AOLV
Inverse input of setting value 50.
-
151
Wire Length
Correction 1
Inverse Input
V/f CL-V/f OLV CLV AOLV
Inverse input of setting value 51.
-
152
Wire Length
Correction 2
Inverse Input
V/f CL-V/f OLV CLV AOLV
Inverse input of setting value 52.
-
153
Wire Length
Correction 3
Inverse Input
V/f CL-V/f OLV CLV AOLV
Inverse input of setting value 53.
-
◆
Multi-Function Digital Outputs (H2-
)
H2 Multi-Function Digital Outputs
Setting
Value
Function
Description
Ref.
50
During Anti Swing
Control
V/f CL-V/f OLV CLV AOLV
Allows you to check the control status of Anti Swing Control when S9-11 = 1
[Anti-Swing Control Selection Enabled]. This output terminal is closed when
Anti Swing Control is active.
7
150
During Anti Swing
Control
Inverse Output
V/f CL-V/f OLV CLV AOLV
Inverse output of setting value 50.
-
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...