Code
Name
Causes
Possible Solutions
Electrical interference caused a communication data
error.
•
Examine the control circuit lines, main circuit lines, and
ground wiring, and decrease the effects of electrical
interference.
•
Make sure that a magnetic contactor is not the source of the
electrical interference, then use a Surge Protective Device if
necessary.
•
Use only the recommended cables or other shielded line.
Ground the shield on the controller side or the drive input
power side.
•
Separate the communication wiring from drive power lines,
and install a noise filter to the input side of the power supply
for communication.
•
Decrease the effects of electrical interference from the
controller.
Note:
•
The drive detects this error if it does not correctly receive control data for the
CE
detection time set to
H5-09 [CE Detection Time]
.
•
Do a Fault Reset to clear the fault.
•
If the drive detects this error, the drive will operate the motor as specified by the stopping method set in
H5-04 [Communication Error Stop Method]
.
Code
Name
Causes
Possible Solutions
CF
Control Fault
Motor parameters are set improperly.
Correctly set the motor parameters and do Auto-Tuning again.
The torque limit is too low.
Adjust
L7-01 to L7-04 [Torque Limit]
.
The load inertia is too big.
•
Adjust
C1-02, C1-04, C1-06, and C1-08 [Deceleration Times]
.
•
Set the frequency reference to the minimum output frequency,
and stop the Run command when the drive stops deceleration.
The drive is trying to ramp to stop a machine that
cannot do ramp to stop or on a machine for which
deceleration is not necessary.
Correctly set
b1-03 [Stopping Method Selection]
.
The motor and drive are connected incorrectly.
Correct wiring errors.
Line-to-line Resistance Tuning is not done.
Do Stationary Auto-Tuning for Line-to-Line Resistance.
The drive received a Run command while the motor
was coasting.
Reevaluate the sequence to ensure that the Run command is input
after the motor has come to a complete stop.
Note:
•
The drive detects this error if the torque reference is more than the torque limit for 3 seconds or longer while the drive ramps to stop.
•
Do a Fault Reset to clear the fault.
Code
Name
Causes
Possible Solutions
CnT1
Number of Driving Over
U4-53 [Num of Driv 1 (Low)]
or
U4-54 [Num of
Driv 1 (High)]
is more than the setting value of
S2-
13 [Motor1 Number of Driving Limit]
.
1. Adjust
S2-09 [Motor1 Number of Driving start]
so that the
number of motor 1 operation starts does not trigger the output
of the warning.
2. Input the fault reset signal.
Note:
•
Do a Fault Reset to clear the fault.
•
The operation of the drive when this fault is detected is determined by
S2-12 [MentenanceTimer Output Selection]
.
Code
Name
Causes
Possible Solutions
CnT2
Number of Driving Over
U4-55 [Num of Driv 2 (Low)]
or
U4-56 [Num of
Driv 2 (High)]
is more than the setting value of
S2-
14 [Motor2 Number of Driving Limit]
.
1. Adjust
S2-10 [Motor2 Number of Driving start]
so that the
number of motor 2 operation starts does not trigger the output
of the warning.
2. Input the fault reset signal.
Note:
•
Do a Fault Reset to clear the fault.
•
The operation of the drive when this fault is detected is determined by
S2-12 [MentenanceTimer Output Selection]
.
Code
Name
Causes
Possible Solutions
CnT3
Number of Driving Over
U4-57 [Num of Driv 3 (Low)]
or
U4-58 [Num of
Driv 3 (High)]
is more than the setting value of
S2-
15 [Motor3 Number of Driving Limit]
.
1. Adjust
S2-11 [Motor3 Number of Driving start]
so that the
number of motor 3 operation starts does not trigger the output
of the warning.
2. Input the fault reset signal.
Note:
•
Do a Fault Reset to clear the fault.
•
The operation of the drive when this fault is detected is determined by
S2-12 [MentenanceTimer Output Selection]
.
Code
Name
Causes
Possible Solutions
CoF
Current Offset Fault
Drive starts operation while the induced voltage
remains in the motor (during coasting to a stop or
after rapid deceleration).
Specify a sequence in which operation is not restarted when
induced voltage remains in the motor.
A drive hardware problem occurred.
Replace the drive.
Note:
•
Detected if the current offset value exceeds the allowable setting range while the drive automatically adjusts the current offset.
•
Perform Fault Reset to clear the fault.
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...