YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
699
Note:
Refer to
Travel Limit Function on page 215
for details.
■
34: Reverse Travel Limit (N.C.)
Setting Value
Function
Description
34
Reverse Travel Limit (N.C.)
If you turn off a terminal while a motor rotates in reverse, the drive turns off the brake release command (holds the brake), the
motor coasts to stop, and the output frequency becomes 0. If you turn off a terminal while a motor rotates forward, the motor
will not stop.
ON : Enables the reverse operation Run command.
OFF : Disables the reverse operation Run command.
Note:
Refer to
Travel Limit Function on page 215
for details.
■
35: Impact Stop Enable
Setting Value
Function
Description
35
Impact Stop Enable
When the terminal is ON and the drive receives a stop command while the output frequency is more than the impact stop creep
frequency, the drive decelerates until it is at the set impact stop creep frequency.
ON : Enables the Impact Stop function.
OFF : Cancel the Impact Stop function and turn OFF the brake release command.
Note:
Refer to
Impact Stop Function on page 206
for details.
■
36: Light-load Accel 2 Enabled
Setting Value
Function
Description
36
Light-load Accel 2 Enabled
Enables or disables the selection of Light-Load Accel 2 Enabled function.
ON : Enabled
OFF : Disabled
Note:
Refer to
Light-load Acceleration 2 Function on page 210
for details.
■
37: Multi-Step Speed Reference 4
Setting Value
Function
Description
37
Multi-Step Speed Reference
4
Uses speed references
d1-01 to d1-16
to set a multi-step speed reference.
Note:
•
On drives with software versions PRG: 01021 and later, this function is enabled.
The
“
PRG
”
column on the nameplate on the right side of the drive identifies the software version. You can also use
U1-25
[SoftwareNumber FLASH]
to identify the software version.
•
Refer to
Setting Procedures for Multi-step Speed Operation on page 622
for more information.
■
38: Counterweight Selection
Setting Value
Function
Description
38
Counterweight Selection
Switch
C4-02 [Torque Compensation Delay Time]
,
E1-08 [Mid Point A Voltage]
and
E1-10 [Minimum Output Voltage]
. The
drive decides parameters based on the combination of the condition of the terminals ON or OFF and Run command orientation
(Forward/Reverse).
Note:
Refer to
Parameter Switching Function for Reverse Operation on page 220
for details.
■
39: Motor 3 Selection
Setting Value
Function
Description
39
Motor 3 Selection
Switches motor 1 or motor 2 to motor 3. Switch the motor while the motor is stopped.
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...