EZZ023535
28 / 35
4.3
H2: Multi-Function Digital Output Settings
Setting Value
Function
Description
53
Slave Pos Dev
ON: Position deviation has exceeded Slave Dev Lvl (SA-46).
Note: Enabled only when set to Position Synchronization mode.
54
Align Complete
The output turns ON when Alignment processing has completed.
The output turns OFF under the following circumstances.
• The accumulated distance has exceeded the total value of SA-63 and
SA-64 when the first trigger was detected.
• A fault occurred and the slave stopped. Or position deviation was cleared
or disabled.
• The Advance Slave or Retard Slave command was input.
• The multi-function digital input terminal allocated to Align Cmd was turned
ON when SA-61 was set to 1 or 2.
• The multi-function digital input terminal allocated to Master Trigger or Slave
Trigger was turned ON when SA-61 was set to 3 or 4.
55
In Alignment
The output turns ON when the deviation between the two triggers is the
setting value of SA-64 or less.
The output turns OFF under the following circumstances.
• The accumulated distance has exceeded the total value of SA-63 and
SA-64 when the first trigger was detected.
• A fault occurred and the slave stopped. Or position deviation was cleared
or disabled.
• The Advance Slave or Retard Slave command was input.
4.4
H3: Multi-Function Analog Input Settings (H3-02/H3-06/H3-10)
Setting Value
Function
Description
Analog Output Scale
29
Analog Ratio Adj
Adjusts the analog input value of the digital gear
ratio. The digital gear ratio is the total value of the
parameter setting value, analog input value, MOP
output value, and communication input value.
10 V: 100.00%
4.5
SA: Crane Special Func
No.
(Hex.)
Name
Description
Default Setting
(Range)
Ref.
SA-31
(1ABA)
Expert
Slave Mode
Selects the Slave mode.
0: Disabled
1: Speed
2: Position
0
(0 - 2)
7
SA-32
(1ADF)
Expert
Speed/Position Sync
Control @Dec
Selects whether or not to perform speed and
position synchronization during ramp to stop.
0: Disabled
1: Enabled
1
(0, 1)
8
SA-33
(1ABB)
RUN
Expert
Ratio Num
High
Sets the upper four digits of the numerator of
the mechanical gear ratio.
1000
(0 - 9999)
9
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...