EZZ023534<1>
6 / 21
S9-03 Hook Position Information Reset
Sets the setting value of this parameter to 1 to zero reset U9-01 [Hook Position (NumR)].
No.
Name
Setting Range
Default Setting
S9-03
Hook Position Information Reset
0, 1
0
0: Disabled
1: Enabled
After U9-01 is reset, the setting value of S9-03 is automatically reset to 0.
S9-04 Hook RangeLim Number of Rotation
Sets the number of motor rotations when moving from the hoisting limit position (forward
travel limit activation position) to the lowering limit position (reverse travel limit activation
position).
No.
Name
Setting Range
Default Setting
S9-04
Hook RangeLim Number of Rotation
0 to 20000 rotations
10000 rotations
S9-05 AO 0V Reference Hook Position
Selects whether to set the hoisting limit position or the lowering limit position as the reference
position when the wire length is set to an analog output (AO). The analog signal is 0 V at the
selected reference position.
No.
Name
Setting Range
Default Setting
S9-05
AO 0V Reference Hook Position
0, 1
0
0: Forward Limit Position
Forward travel limit activation position: 0 V, reverse travel limit activation position: 10 V
1: Lower Limit Position
Reverse travel limit activation position: 0 V, forward travel limit activation position: 10 V
S9-06 Motion Range Over Detect Select
Displays the oor alarm when the setting value of S9-04 [Hook RangeLim Number of Rotation]
is exceeded.
No.
Name
Setting Range
Default Setting
S9-06
Motion Range Over Detect Select
0, 1
0
0: Disabled
1: Enabled
S9-07 Home Position Number of Rotation
Sets the value that will overwrite U9-01 (Hook Position) as the number of motor rotations when
Home Position Set signal is input. For this setting value, set the number of motor rotations from
the hoisting limit position to the home position (an arbitrary position).
No.
Name
Setting Range
Default Setting
S9-07
Home Position Number of Rotation
0 to 20000 rotations
0 rotations
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...