678
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
■
F6-58: DeviceNet Torque Scaling
No.
(Hex.)
Name
Description
Default
(Range)
F6-58
(03D9)
DeviceNet Torque Scaling
Sets the torque scale of the DeviceNet communication master.
0
(-15 - +15)
■
F6-59: DeviceNet Power Scaling
No.
(Hex.)
Name
Description
Default
(Range)
F6-59
(03DA)
DeviceNet Power Scaling
Sets the power scale of the DeviceNet communication master.
0
(-15 - +15)
■
F6-60: DeviceNet Voltage Scaling
No.
(Hex.)
Name
Description
Default
(Range)
F6-60
(03DB)
DeviceNet Voltage Scaling
Sets the voltage scale of the DeviceNet communication master.
0
(-15 - +15)
■
F6-61: DeviceNet Time Scaling
No.
(Hex.)
Name
Description
Default
(Range)
F6-61
(03DC)
DeviceNet Time Scaling
Sets the time scale of the DeviceNet communication master.
0
(-15 - +15)
■
F6-62: DeviceNet Heartbeat Interval
No.
(Hex.)
Name
Description
Default
(Range)
F6-62
(03DD)
DeviceNet Heartbeat
Interval
Sets the heartbeat for DeviceNet communication. Set this parameter to 0 to disable the heartbeat
function.
0
(0 - 10)
■
F6-63: DeviceNet Network MAC ID
No.
(Hex.)
Name
Description
Default
(Range)
F6-63
(03DE)
DeviceNet Network MAC
ID
Sets the function to see the actual DeviceNet MAC address using the keypad. This parameter
functions as a monitor only.
0
(0 - 63)
■
F6-64 to F6-67: Dynamic Out Assembly 109 Param1 to 4
No.
(Hex.)
Name
Description
Default
(Range)
F6-64 to F6-67
(03DF - 03E2)
Dynamic Out Assembly
109 Param 1 to 4
Sets Configurable Outputs 1 to 4 written to the MEMOBUS register.
0000H
(0000H - FFFFH)
■
F6-68 to F6-71: Dynamic In Assembly 159 Param 1 to 4
No.
(Hex.)
Name
Description
Default
(Range)
F6-68 to F6-71
(03E3, 03E4,
03C7, and 03C8)
Dynamic In Assembly 159
Param 1 to 4
Sets Configurable Inputs 1 to 4 read from the MEMOBUS register.
0000H
(0000H - FFFFH)
■
F6-72: PowerLink Node Address
No.
(Hex.)
Name
Description
Default
(Range)
F6-72
(081B)
PowerLink Node Address
Sets the node ID for PowerLink communication.
0
(0 - 255)
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...