3.10 Crane Application Setup Procedure
224
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
Note:
If the resulting frequency reference after having been multiplied by the gain of
S2-16
or
S2-17
is less than the frequency reference lower
limit, this lower limit value will be used. The frequency reference lower limit is the maximum setting value for the following
parameters.
•
d2-02 [Frequency Reference Lower Limit]
•
S1-01 [Brake Release Frequency(FWD)]
•
S1-02 [Brake Release Frequency(REV)]
•
S1-12 [Brake Hold Frequency (FWD)]
•
S1-13 [Brake Hold Frequency (REV)]
■
MFDI
H1-xx
Setting
Name
Description
3A
Micro Speed Gain1
When the corresponding terminal is on, the frequency reference is multiplied by the gain set to
S2-16 [Micro Speed Gain1]
.
3B
Micro Speed Gain2
When the corresponding terminal is on, the frequency reference is multiplied by the gain set to
S2-17 [Micro Speed Gain2]
.
Note:
When the frequency reduction gain 1 input is on, the gain set to
S2-16 [Micro Speed Gain1]
has priority.
■
Description of Operation
◆
Rapid Deceleration Function
The deceleration rate can be changed to rapidly stop operation by inputting a Run command in reverse to the
current running direction during the ramp to stop operation. This enables quick deceleration near the target
location even when using high-speed operation.
■
Description of Operation
Set
S2-18 = 1 [Rapid Deceleration Selection = Enabled]
to enable this function.
When deceleration starts after the Run command is turned off, and a Run command in reverse to the current
direction of motor rotation is input, the motor rapidly decelerates per the time set to
S2-19 [Rapid Deceleration
Time]
. When the Run command is turned off during rapid deceleration, rapid deceleration is turned off, and the
motor continues to decelerate at the selected normal deceleration rate.
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...