Inputs the voltage signal of -10 V to 10 V. This setting enables positive and negative polarity signals. When this
setting is used as the frequency reference, the motor runs reverse when the Forward run command is input, or runs
forward when the reverse run signal is input, while the signal is a negative number due to the gain and bias
adjustment.
■
H3-02: Terminal A1 Function Selection
No.
(Hex.)
Name
Description
Default
(Range)
H3-02
(0434)
Terminal A1 Function
Selection
Sets the function for MFAI terminal A1.
0
(0 - FF)
■
H3-03: Terminal A1 Gain Setting
No.
(Hex.)
Name
Description
Default
(Range)
H3-03
(0411)
RUN
Terminal A1 Gain Setting
Sets the gain of the analog signal input to MFAI terminal A1.
100.0%
(-999.9 - +999.9%)
This parameter sets the command reference amount for the function set for terminal A1 as a percentage when 10
V is input.
Use
H3-03 and H3-04 [Terminal A1 Bias Setting]
to adjust the characteristics of the analog input signal to
terminal A1.
■
H3-04: Terminal A1 Bias Setting
No.
(Hex.)
Name
Description
Default
(Range)
H3-04
(0412)
RUN
Terminal A1 Bias Setting
Sets the bias of the analog signal input to MFAI terminal A1.
0.0%
(-999.9 - +999.9%)
This parameter sets the bias for the function set for terminal A1 as a percentage when 0 V is input.
Use
H3-03 [Terminal A1 Gain Setting] and H3-04
to adjust the characteristics of the analog input signal to
terminal A1.
■
H3-05: Terminal A3 Signal Level Select
No.
(Hex.)
Name
Description
Default
(Range)
H3-05
(0413)
Terminal A3 Signal Level
Select
Sets the input signal level for MFAI terminal A3.
0
(0, 1)
0 : 0 to 10 V (Lower Limit at 0)
Inputs the voltage signal of 0 V to 10 V. The signal is reset to 0% when it becomes a negative number due to gain
and bias adjustment.
1 : -10 to +10V (Bipolar Reference)
Inputs the voltage signal of -10 V to 10 V. This setting enables positive and negative polarity signals. When this
setting is used as the frequency reference, the motor runs reverse when the Forward run command is input, or runs
forward when the reverse run signal is input, while the signal is a negative number due to the gain and bias
adjustment.
■
H3-06: Terminal A3 Function Selection
No.
(Hex.)
Name
Description
Default
(Range)
H3-06
(0414)
Terminal A3 Function
Selection
Sets the function for MFAI terminal A3.
2
(0 - FF)
Note:
When using terminal A3 as the PTC input terminal, set
H3-06 = E [Motor Temperature (PTC Input)]
, and set DIP switch S4 to the PTC
side.
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...