682
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
Note:
Set this parameter to 0.0 to disable the connection timeout function.
■
F7-17: EtherNet/IP Speed Scaling Factor
No.
(Hex.)
Name
Description
Default
(Range)
F7-17
(03F5)
EtherNet/IP Speed Scaling
Factor
Sets the scaling factor for the speed monitor in the EtherNet/IP Class ID 2AH Object.
0
(-15 - +15)
■
F7-18: EtherNet/IP Current Scale Factor
No.
(Hex.)
Name
Description
Default
(Range)
F7-18
(03F6)
EtherNet/IP Current Scale
Factor
Sets the scaling factor for the output current monitor in the EtherNet/IP Class ID 2AH Object.
0
(-15 - +15)
■
F7-19: EtherNet/IP Torque Scale Factor
No.
(Hex.)
Name
Description
Default
(Range)
F7-19
(03F7)
EtherNet/IP Torque Scale
Factor
Sets the scaling factor for the torque monitor in the EtherNet/IP Class ID 2AH Object.
0
(-15 - +15)
■
F7-20: EtherNet/IP Power Scaling Factor
No.
(Hex.)
Name
Description
Default
(Range)
F7-20
(03F8)
EtherNet/IP Power Scaling
Factor
Sets the scaling factor for the power monitor in the EtherNet/IP Class ID 2AH Object.
0
(-15 - +15)
■
F7-21: EtherNet/IP Voltage Scale Factor
No.
(Hex.)
Name
Description
Default
(Range)
F7-21
(03F9)
EtherNet/IP Voltage Scale
Factor
Sets the scaling factor for the voltage monitor in the EtherNet/IP Class ID 2AH Object.
0
(-15 - +15)
■
F7-22: EtherNet/IP Time Scaling
No.
(Hex.)
Name
Description
Default
(Range)
F7-22
(03FA)
EtherNet/IP Time Scaling
Sets the scaling factor for the time monitor in the EtherNet/IP Class ID 2AH Object.
0
(-15 - +15)
■
F7-23 to F7-32: Dynamic Out Param 1 to 10 for CommCard
No.
(Hex.)
Name
Description
Default
(Range)
F7-23 to F7-27
(03FB - 03FF)
F7-28 to F7-32
(0370 - 0374)
Dynamic Out Param 1 to 10
for CommCard
When you use an Ethernet/IP option, sets Output Assembly 116. The drive writes the values from
Output Assembly 116 to the MEMOBUS/Modbus address register that is stored for each
parameter. The drive will not write the values from Output Assembly 116 to the registers when
the MEMOBUS/Modbus address is 0. When you use a ProfiNet option, set
F7-23
to
F7-27
to
configurable Output 1-5.
0
■
F7-33 to F7-42: Dynamic In Param 1 to 10 for CommCard
No.
(Hex.)
Name
Description
Default
(Range)
F7-33 to F7-42
(0375 - 037E)
Dynamic In Param 1 to 10
for CommCard
When you use an Ethernet/IP option, sets Input Assembly 166. The drive sends the values from
the MEMOBUS/Modbus address registers stored for each parameter to Input Assembly 166. The
drive returns the default register value for the option card when the MEMOBUS/Modbus address
is 0 and the value sent to Input Assembly 166 is not defined. When you use a ProfiNet option, set
F7-33
to
F7-37
to configurable inputs 1-5.
0
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...