EZZ023534<1>
21 / 21
◆
Alarm
Code
Name
Cause
Possible Solution
oor
Over Operation
Region
The range of the lifting/lowering
operation has exceeded the setting
value of S9-04 [Hook RangeLim
Number of Rotation].
Review the setting value of S9-04 [Hook
RangeLim Number of Rotation].
Detect the origin position with one of the
following options.
•
Hoist the hook to the hoisting limit
position, and then input Forward Travel
Limit or set S9-03
= 1 [Hook Position
Reset].
•
Lower the hook to the lowering limit
position, and then input Reverse Travel
Limit.
•
When using S9-07 [Home Position
Number of Rotation], move the hook to
the home position 2, and then input Home
Position Set.
oPL
Origin Position Loss
Detected
The origin (home) position was not
detected when Wire Length Output
was enabled.
Detect the origin position with one of the
following options.
•
Hoist the hook to the hoisting limit
position, and then input Forward Travel
Limit or set S9-03 = 1 [Hook Position
Reset].
•
Lower the hook to the lowering limit
position, and then input Reverse Travel
Limit.
•
When using S9-07 [Home Position
Number of Rotation], move the hook to
the home position 2, and then input Home
Position Set.
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...