2.9 Change the Drive Enclosure Type
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
59
• 0.98 N
∙
m to 1.33 N
∙
m (8.67 lbf
∙
in to 11.77 lbf
∙
in)
A - Hooks
B - Back side of top protective cover
C - Temporary placement holes
D - M4
×
8 pan head screws
Figure 2.52 Install the Top Protective Cover
■
Install the Conduit Bracket
•
Remove the drive hanging brackets before you install the kit.
•
Remove the knock-out holes on the UL Type 1 base before you install it to the drive.
Refer to
Remove the Knock-Out Holes on page 51
for more information.
1.
Use the included screws to assemble the stay brackets.
Tighten the screws to a correct tightening torque:
• 0.98 N
∙
m to 1.33 N
∙
m (8.67 lbf
∙
in to 11.77 lbf
∙
in)
A - Stay brackets
B - M4
×
8 pan head screws
Figure 2.53 Install the Stay Brackets
2.
Use the included screws to install the UL Type 1 base on the stay brackets.
Tighten the screws to a correct tightening torque:
• 0.98 N
∙
m to 1.33 N
∙
m (8.67 lbf
∙
in to 11.77 lbf
∙
in)
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...