374
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
Code
Name
Causes
Possible Solutions
MFDI
[H1-xx]
Settings for N.C. and N.O. input [H1-
xx] for the following functions are selected at the
same time:
•
Setting Value
15 [Fast Stop (N.O.)]
•
Setting Value
17 [Fast Stop (N.C.)]
Remove one of the function assignments.
H1-xx = 2 [External Reference 1/2 Selection]
is set
at the same time with these parameters.
•
b1-15 = 3 [Frequency Reference Selection 2 =
Option PCB]
or
b1-16 = 3 [Run Command
Selection 2 = Option PCB]
•
No option card is connected to the drive.
Connect an input option card to the drive.
H1-xx = 2 [External Reference 1/2 Selection]
When
xx is set, these parameters are set at the same time
while:
•
b1-15 = 1 [Frequency Reference Selection 2 =
Analog Input]
•
H3-02 ≠ 0 [Terminal A1 Function Selection ≠
Frequency Reference]
or
H3-10 ≠ 0 [Terminal A2
Function Selection ≠ Frequency Reference]
H3-02 = 0
or
H3-10 = 0
Set
The settings are contradictory in these ways:
•
A PG-RT3 is attached to the drive.
•
H1-xx = 16 [Motor 2 Selection]
is set.
Set the parameters correctly.
Note:
Motor Switch function is not available when using the PG-
RT3.
Code
Name
Causes
Possible Solutions
oPE05
Run Cmd/Freq Ref Source Sel Err
The setting to assign the Run command or
frequency reference to an option card is incorrect.
Set the parameters correctly.
Parameter
b1-01 = 3 [Frequency Reference
Selection 1 = Option PCB]
has been set, but an
option card is not connected to the drive.
Parameter
b1-02 = 3 [Run Command Selection 1 =
Option PCB]
has been set, but an option card is not
connected to the drive.
Connect an option card to the drive.
The following parameters are set at the same time:
•
F3-01 = 6 [Digital Input Function Selection =
BCD (5-digit), 0.01 Hz]
•
F3-03 = 0, 1 [DI Data Length Selection = 8bit,
12bit]
Set
F3-03 = 2 [16bit]
.
The following parameters have been set while the
AI-A3 option card is installed:
•
H1-xx = 2 [External Reference 1/2 Selection]
•
b1-15 = 3 [Frequency Reference Selection 2 =
Option PCB]
•
F2-01 = 0 [Analog Input Function Selection = 3
channel individual]
Set the parameters correctly.
Code
Name
Causes
Possible Solutions
oPE06
Control Method Selection Error
A1-02 = 1 or 3 [Control Method Selection = CL-V/
f, CLV]
is set, but there is no encoder option
connected to the drive.
•
Connect an encoder option to the drive.
•
Set
A1-02
correctly.
You supplied external 24 V power to terminals PS-
AC when:
•
There is an encoder option installed the drive
•
The drive main circuit power supply is de-
energized
1. De-energize the drive main circuit power supply and the
external 24 V power supply to terminals PS-AC.
2. After the keypad display goes out, energize the drive main
circuit power supply again.
3. Supply the external 24 V power to terminals PS-AC.
When you use an encoder option, energize the drive main circuit
power supply.
Code
Name
Causes
Possible Solutions
oPE07
Analog Input Selection Error
The settings for
H3-02, H3-06, and H3-10 [MFAI
Function Select]
and
H7-30 [Virtual Analog Input
Selection]
overlap.
Change the settings to
H3-02, H3-06, H3-10, and H7-30
so that
the functions assigned to them no longer overlap.
Note:
These functions can be set to multiple analog input terminals
at the same time:
•
Setting value
0 [Frequency Reference]
•
Setting values
F and 1F [Not Used]
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...