SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
Table 11.19 DI-A3 Terminal Function Selection
Terminal
Block
Terminal
Name
BCD, Signed
[F3-01 = 0 to 5]
BCD, Unsigned
[F3-01 = 6]
Binary, Signed
[F3-01 = 7]
8-bit
[F3-03 = 0]
12-bit
[F3-03 = 1]
16-bit
[F3-03 = 2]
8-bit
[F3-03 =
0]
12-bit
[F3-03 = 1]
16-bit
[F3-03 =
2]
TB2
D0
1 digit (0 -
9)
1
1 digit (0 -
9)
1
1 digit (0 -
9)
1
1 digit (0,
2, 4, 6, 8)
2
bit 0
bit 0
bit 0
D1
2
2
2
4
bit 1
bit 1
bit 1
D2
4
4
4
8
bit 2
bit 2
bit 2
D3
8
8
8
2 digits (0 -
9)
1
bit 3
bit 3
bit 3
D4
2 digits (0 -
1
2 digits (0 -
9)
1
2 digits (0 -
9)
1
2
bit 4
bit 4
bit 4
D5
2
2
2
4
bit 5
bit 5
bit 5
D6
4
4
4
8
bit 6
bit 6
bit 6
D7
8
8
8
3 digits (0 -
9)
1
bit 7
bit 7
bit 7
TB3
D8
-
-
3 digits (0 -
15)
1
3 digits (0 -
9)
-
2
-
bit 8
bit 8
D9
-
2
-
4
-
bit 9
bit 9
DA
-
4
-
8
-
bit 10
bit 10
DB
-
8
-
4 digits (0 -
9)
1
-
bit 11
bit 11
DC
-
-
-
-
4 digits (0 -
-
2
-
-
bit 12
DD
-
-
-
4
-
-
bit 13
DE
-
-
-
8
-
-
bit 14
DF
-
-
-
5 digits (0 -
3)
1
-
-
bit 15
TB1
SI
SIGN (encoded) signal
0: Forward run, 1: Reverse run
2
SIGN (encoded) signal
0: Forward run, 1: Reverse run
SE
SET (loaded) signal
1: Loads the value set for D0 to DF and SI.
SP
Internal power supply: 24 V ± 5%
SC
Input signal common
SN
Internal power supply common: 0 V
SD
Cable sheath connection terminal (ungrounded)
FE
Cable sheath connection terminal (grounded)
*1
Setting
F3-03 = 2 [Digital Input Data Length Select = 16-bit]
enables
F3-01 = 6 [Digital Input Function Selection = BCD (5-digit),
0.01 Hz]
and a frequency between 0.00 Hz to 399.8 Hz can be set by the BCD. Note that terminal SI is also used as for data bits.
Negative commands cannot be input as encoding information (positive/negative) cannot be added to the data.
The minimum bit value for the first BCD digit is 2. For this reason, 0.02 Hz is the smallest setting unit available for this frequency
setting. An
oPE05 [Run Cmd/Freq Ref Source Sel Err]
occurs when
F3-03 ≠ 2
while
F3-01 = 6
.
*2
The most significant digit can be set to a value between 0 to 15 when using
“
BCD, Signed
”
. Other digits can be set to a value between
0 to 9.
■
F3-10: Terminal D0 Function Selection
No.
(Hex.)
Name
Description
Default
(Range)
F3-10
(0BE3)
Expert
Terminal D0 Function
Selection
Sets the function for terminal D0 of the DI-A3 option when
F3-01 = 8 [Digital Input Function
Selection = Multi-Function Digital Input]
.
F
(0 - 1FF)
■
F3-11: Terminal D1 Function Selection
No.
(Hex.)
Name
Description
Default
(Range)
F3-11
(0BE4)
Expert
Terminal D1 Function
Selection
Sets the function for terminal D1 of the DI-A3 when
F3-01 = 8 [Digital Input Function Selection
= Multi-Function Digital Input]
.
F
(0 - 1FF)
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...