2.9 Change the Drive Enclosure Type
60
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
Note:
The number of screws are different for different models.
•100-192-121-007: 4 screws
•100-192-121-008: 6 screws
A - M4
×
8 pan head screws
B - Base
Figure 2.54 Install the Base on the Stay Brackets
3.
Use the included bolts to install the UL Type 1 base to the drive.
Tighten the bolts to a correct tightening torque:
• M6
×
16 upset bolts 3.92 N
∙
m to 4.90 N
∙
m (34.70 lbf
∙
in to 43.37 lbf
∙
in)
• M8
×
16 hex bolts: 8.83 N
∙
m to 10.79 N
∙
m (78.15 lbf
∙
in to 95.49 lbf
∙
in)
A - M6
×
16 upset head bolts
B - M8
×
16 hex bolts
C - M8 plain washers
D - Base
Figure 2.55 Safety the Base
4.
Use the included screws to install the UL Type 1 conduit bracket to the base.
Tighten the screws to a correct tightening torque:
• 0.98 N
∙
m to 1.33 N
∙
m (8.67 lbf
∙
in to 11.77 lbf
∙
in)