YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
475
◆
C2: S-Curve Characteristics
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
C2-01
(020B)
S-Curve Time @ Start of
Accel
Sets the S-curve acceleration time at start.
Determined by A1-02
(0.00 - 10.00 s)
C2-02
(020C)
S-Curve Time @ End of
Accel
Sets the S-curve acceleration time at completion.
0.20 s
(0.00 - 10.00 s)
C2-03
(020D)
S-Curve Time @ Start of
Decel
Sets the S-curve deceleration time at start.
0.20 s
(0.00 - 10.00 s)
C2-04
(020E)
S-Curve Time @ End of
Decel
Sets the S-curve deceleration time at completion.
0.00 s
(0.00 - 10.00 s)
◆
C3: Slip Compensation
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
C3-01
(020F)
RUN
Slip Compensation Gain
Sets the gain for the slip compensation function. Usually it is not necessary to change
this setting.
Note:
•
Correctly set these parameters before you change the slip compensation gain:
When
A1-02 = 2 [Control Method Selection = Open Loop Vector]
, you can use
Auto-Tuning to set
E2-02 [Motor Rated Slip]
.
–
E2-01 [Motor Rated Current (FLA)]
–
E2-02 [Motor Rated Slip]
–
E2-03 [Motor No-Load Current]
•
When
A1-02 = 4 [Advanced Open Loop Vector]
, you cannot change the setting
while the drive is running.
Determined by A1-02
(0.0 - 2.5)
C3-02
(0210)
RUN
Slip Compensation
Delay Time
Sets the slip compensation delay time when speed is unstable or when the slip
compensation response is too slow. Usually it is not necessary to change this setting.
Determined by A1-02
(0 - 10000 ms)
C3-03
(0211)
Slip Compensation Limit
Sets the upper limit for the slip compensation function as a percentage of the motor
rated slip.
200%
(0 - 250%)
C3-04
(0212)
Slip Compensation at
Regen
Sets the slip compensation function during regenerative operation.
0 : Disabled
1 : Enabled Above 6Hz
2 : Enabled Above C3-15
0
(0 - 2)
C3-05
(0213)
Output Voltage Limit
Selection
Sets the automatic reduction of motor magnetic flux when the output voltage is
saturated.
0 : Disabled
1 : Enabled
0
(0, 1)
C3-16
(0261)
Expert
Vout Modulation Limit
Start Lvl
Sets the modulation factor that starts the output voltage limit operation when
C3-05 = 1
[Output Voltage Limit Selection = Enabled]
.
90.0%
(70.0 - 90.0%)
C3-17
(0262)
Expert
Vout Modulation Limit
Max Level
Sets the modulation factor used with
C3-18 [Output Voltage Limit Level]
for the output
voltage limit operation when
C3-05 = 1 [Output Voltage Limit Selection = Enabled]
.
100.0%
(85.0 - 100.0%)
C3-18
(0263)
Expert
Output Voltage Limit
Level
Sets the maximum drop width of the voltage reference when
C3-05 = 1 [Output Voltage
Limit Selection = Enabled]
.
90.0%
(50.0 - 100.0%)
C3-21
(033E)
RUN
Motor 2 Slip
Compensation Gain
Sets the gain for the motor 2 slip compensation function. Usually it is not necessary to
change this setting.
Note:
Correctly set these parameters before changing the slip compensation gain:
•
E4-01 [Motor 2 Rated Current]
•
E4-02 [Motor 2 Rated Slip]
•
E4-03 [Motor 2 Rated No-Load Current]
Determined by E3-01
(0.0 - 2.5)
C3-22
(0241)
RUN
Motor 2 Slip Comp
Delay Time
Sets the slip compensation delay time for motor 2 when speed is unstable or when the
slip compensation response is too slow. Usually it is not necessary to change this
setting.
Determined by E3-01
(0 - 10000 ms)
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...