6.3 List of Fault, Minor Fault, Alarm, and Error Codes
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
339
Display (Hex.)
Name
ALM LED
Type
Ref.
Er-14
Motor Speed Error 2
Flashing
Auto-Tuning Error
Er-15
Torque Saturation Error
Flashing
Auto-Tuning Error
Er-16
Inertia ID Error
Flashing
Auto-Tuning Error
Er-17
Reverse Prohibited Error
Flashing
Auto-Tuning Error
Err (001F)
EEPROM Write Error
Illuminated
Fault
FAn (000F)
Internal Fan Fault
Flashing
Alarm
FAn (0017)
Internal Fan Fault
Illuminated
Fault
FAn1 (0413)
Drive Cooling Fan Fault
Illuminated
Fault
(0071)
Input During Forward run Limit
Flashing
Alarm
GF (0006)
Ground Fault
Illuminated
Fault
HCA (0034)
High Current Alarm
Flashing
Alarm
iFEr
Communication Err
-
Copy Function Error
L24v (0021)
Loss of External Power 24 Supply
Flashing
Alarm
LF (001C)
Output Phase Loss
Illuminated
Fault
LoG
Log Com Error
Flashing
Alarm
LT-1 (0035)
Cooling Fan Maintenance Time
Flashing
Alarm
LT-2 (0036)
Capacitor Maintenance Time
Flashing
Alarm
LT-3 (0043)
SoftChargeBypassRelay MainteTime
Flashing
Alarm
LT-4 (0044)
IGBT Maintenance Time (50%)
Flashing
Alarm
ndAT
Error Received Data
-
Copy Function Error
nSE (0052)
Node Setup Error
Illuminated
Fault
oC (0007)
Overcurrent
Illuminated
Fault
oFA00 (0101)
Option Not Compatible with Port
Illuminated
Fault
oFA01 (0102)
Option Fault/Connection Error
Illuminated
Fault
oFA02 (0103)
Duplicate Options
Illuminated
Fault
oFA03 to oFA06 (0104 to 0107)
Option Card Error at Option Port (CN5-A)
Illuminated
Fault
-
oFA10, oFA11 (0111, 0112)
Option Card Error at Option Port (CN5-A)
Illuminated
Fault
,
oFA12 to oFA17 (0113 to 0118)
Option Card Error at Option Port (CN5-A)
Illuminated
Fault
-
oFA30 to oFA43 (0131 to 013E)
Communication Option Card Connection Error (CN5-A)
Illuminated
Fault
-
oFb00 (0201)
Option Not Compatible with Port
Illuminated
Fault
oFb01 (0202)
Option Fault/Connection Error
Illuminated
Fault
oFb02 (0203)
Duplicate Options
Illuminated
Fault
oFb03 to oFb11 (0204 to 0212)
Option Card Error at Option Port (CN5-B)
Illuminated
Fault
-
oFb12 to oFb17 (0213 to 0218)
Option Card Error at Option Port (CN5-B)
Illuminated
Fault
-
oFC00 (0301)
Option Not Compatible with Port
Illuminated
Fault
oFC01 (0302)
Option Fault/Connection Error
Illuminated
Fault
oFC02 (0303)
Duplicate Options
Illuminated
Fault
oFC03 to oFC11 (0304 to 0312)
Option Card Error at Option Port (CN5-C)
Illuminated
Fault
-
oFC12 to oFC17 (0313 to 0318)
Option Card Error at Option Port (CN5-C)
Illuminated
Fault
-
oFC50 to oFC55 (0351 to 0356)
Option Card Error at Option Port (CN5-C)
Illuminated
Fault
-
oH (0003)
Heatsink Overheat
Flashing
Alarm
oH (0009)
Heatsink Overheat
Illuminated
Fault
oH1 (000A)
Heatsink Overheat
Illuminated
Fault
oH2 (0004)
External Overheat (H1-XX=B)
Flashing
Alarm
oH3 (0022)
Motor Overheat (PTC Input)
Flashing
Alarm
oH3 (001D)
Motor Overheat (PTC Input)
Illuminated
Fault
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...