EZZ023536
11/16
SA-10 Load Share on level2
Sets start level 2 for slave Load Share. This parameter enables Load Share when the
absolute value of the deviation between the master and slave torque signal (torque/current)
is greater than start level 2. Set this parameter to 0.0% to keep slave Load Share constantly
enabled.
This parameter is set as a percentage of motor rated torque.
No.
Name
Setting Range
Default Setting
SA-10
Load Share on level2
0.0% to 100.0%
0.0%
Figure 3.8 Switching Load Share between Enabled and Disabled
The following table gives the relationship between enabling and disabling Load Share when
the conditions for Load Share On Lvl1/Lvl2 are satisfied.
Table 3.1 Relationship between Enabling and Disabling Load Share
Start Level 1
Condition ON
Start Level 1
Condition OFF
Start Level 2
Condition ON
Enabled
Enabled
Start Level 2
Condition OFF
Enabled
Disabled
Start level 2 (SA-10)
Load Share
Disabled
Enabled
Disabled
Master torque signal -
Slave torque signal
Deviation between master and slave torque signal
(absolute value)
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...