No.
Name
Default
Function
H2-01
Multi-Function Digital Output 1 (contact)
21
Brake Release Command
H2-02
Multi-Function Digital Output 2 (contact)
0
During Run
H2-03
Multi-Function Digital Output 3 (contact)
2
Speed Agree 1
H2-04
Multi-Function Digital Output 4 (open-
collector)
6
Drive Ready
H2-05
Multi-Function Digital Output 5 (open-
collector)
10
Alarm
Refer to the following table when setting
H2-xx [MFDO Function Selection]
.
Table 11.29 MFDO Setting Value
Setting Value
Function
0
During Run
1
Zero Speed
2
Speed Agree 1
3
User-Set Speed Agree 1
4
Frequency Detection 1
5
Frequency Detection 2
6
Drive Ready
7
DC Bus Undervoltage
8
During Baseblock (N.O.)
9
Frequency Reference from Keypad
A
Run Command from Keypad
B
Torque Detection 1 (N.O.)
C
Frequency Reference Loss
D
Braking Resistor Fault
E
Fault
F
Not Used
10
Alarm
11
Fault Reset Command Active
13
Speed Agree 2
14
User-Set Speed Agree 2
15
Frequency Detection 3
16
Frequency Detection 4
17
Torque Detection 1 (N.C.)
18
Torque Detection 2 (N.O.)
19
Torque Detection 2 (N.C.)
1A
During Reverse
1B
During Baseblock (N.C.)
1C
Motor 2 Selection
1D
During Regeneration
1F
Motor Overload Alarm (oL1)
20
Drive Overheat Pre-Alarm (oH)
Setting Value
Function
21
Brake Release Command
22
Overload Detection (N.O.)
23
Weight Det N.C.
2F
Maintenance Notification
30
During Torque Limit
33
Zero Servo Complete
37
During Frequency Output
39
Watt Hour Pulse Output
3C
LOCAL Control Selected
4C
During Fast Stop
4D
oH Pre-Alarm Reduction Limit
4E
Braking Transistor Fault (rr)
Braking Resistor Overheat (rH)
51
Safe Torque OFF
52
Warning Signal
60
Internal Cooling Fan Failure
62
Modbus Reg 1 Status Satisfied
63
Modbus Reg 2 Status Satisfied
66
Comparator1
67
Comparator2
69
External Power 24V Supply
6A
Data Logger Error
6C
Motor Start Speed Warning Signal
B1
DC Injection Braking at Start
B2
DC Injection Braking at Stop
B3
Motor 3 Selection
100 to 1FF
Inverse output of 0 to FF
Generates inverse output of the function
for the selected MFDO. Sets the function
for which to generate inverse output by
specifying the last 2 digits of 1xx (00 to
FF).
*1
Inverse output is not available.
*2
This parameter cannot be set on models 2145 to 2415 and 4075 to 4605.
■
Extended MFDO1 to MFDO3 Function Selection
You can set MFDO functions to
bit 0 to bit 2 [MEMOBUS MFDO1 to 3]
of MEMOBUS register 15E0 (Hex.).
Use
H2-40 to H2-42 [Mbus Reg 15E0h bit0 to bit2 Output Func]
to select the function.
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...