C3-21: Motor 2 Slip Compensation Gain
No.
(Hex.)
Name
Description
Default
(Range)
C3-21
(033E)
RUN
Motor 2 Slip Compensation
Gain
Sets the gain for the motor 2 slip compensation function. Usually it is not necessary to change this
setting.
Determined by E3-01
(0.0 - 2.5)
Note:
Correctly set these parameters before you change the slip compensation gain:
•
E4-01 [Motor 2 Rated Current]
•
E4-02 [Motor 2 Rated Slip]
•
E4-03 [Motor 2 Rated No-Load Current]
Adjust this parameter as follows if necessary:
•
If the motor speed is slower than the frequency reference, increase
C3-01
in 0.1-unit increments.
•
If the motor speed is faster than the frequency reference, decrease
C3-01
in 0.1-unit increments.
■
C3-22: Motor 2 Slip Comp Delay Time
No.
(Hex.)
Name
Description
Default
(Range)
C3-22
(0241)
RUN
Motor 2 Slip Comp Delay
Time
Sets the slip compensation delay time for motor 2 when speed is unstable or when the slip
compensation response is too slow. Usually it is not necessary to change this setting.
Determined by E3-01
(0 - 10000 ms)
Use these settings to adjust this parameter as necessary:
•
When the speed is not stable, increase the setting.
•
When the slip compensation response is too slow, decrease the setting.
■
C3-23: Motor 2 Slip Compensation Limit
No.
(Hex.)
Name
Description
Default
(Range)
C3-23
(0242)
Motor 2 Slip Compensation
Limit
Sets the upper limit for the slip compensation function as a percentage of the motor 2 rated slip.
200%
(0 - 250%)
If you increase the value of
C3-21 [Motor 2 Slip Compensation Gain]
and the motor speed is slow, use this
parameter. The drive uses this parameter when the slip is at the upper limit of slip compensation. Make sure that
you measure the motor speed when you increase this parameter value. Set this parameter to make the frequency
reference and the slip compensation limit less than the permitted range of the machine.
The slip compensation limit is constant in the constant torque range (frequency reference ≤
E3-06 [Motor 2 Base
Frequency]
). In the constant power range where the frequency reference >
E3-06
, the slip compensation limit
increases with the
C3-23
value and the output frequency as shown in
.
Figure 11.34 Motor 2 Slip Compensation Limit
■
C3-24: Motor 2 Slip Comp during Regen
No.
(Hex.)
Name
Description
Default
(Range)
C3-24
(0243)
Motor 2 Slip Comp during
Regen
Sets the slip compensation during regenerative operation function for motor 2.
0
(0 - 2)
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...