802
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
■
T1-06: Number of Motor Poles
No.
(Hex.)
Name
Description
Default
(Range)
T1-06
(0706)
Number of Motor Poles
Sets the number of motor poles.
4
(2 - 120)
■
T1-07: Motor Base Speed
No.
(Hex.)
Name
Description
Default
(Range)
T1-07
(0707)
Motor Base Speed
Sets the motor base speed for Auto-Tuning (min
-1
(r/min)).
1750 min
-1
(r/min)
(0 - 35400 min
-1
(r/min))
■
T1-08: Encoder Pulse Count (PPR)
No.
(Hex.)
Name
Description
Default
(Range)
T1-08
(0708)
Encoder Pulse Count (PPR)
Sets the number of PG (pulse generator, encoder) pulses.
600 ppr
(0 - 60,000 ppr)
Set the actual number of pulses for one full motor rotation.
■
T1-09: Motor No-Load Current
No.
(Hex.)
Name
Description
Default
(Range)
T1-09
(0709)
Motor No-Load Current
Sets the no-load current of the motor.
-
(0A - T1-04; max. of
2999.9)
Note:
The display units are different for different models:
•
2003 to 2033, 4002 to 4018: 0.01 A units
•
2047 to 2415, 4024 to 4605: 0.1 A units
The value shown is the no-load current that is automatically calculated from the values set in
T1-02 [Motor Rated
Power]
and
T1-04 [Motor Rated Current]
. Set the no-load current shown on the motor test report. If the motor
test report is not available, do not change this parameter.
■
T1-10: Motor Rated Slip Frequency
No.
(Hex.)
Name
Description
Default
(Range)
T1-10
(070A)
Motor Rated Slip
Frequency
Sets motor rated slip.
-
(0.000 - 20.000 Hz)
Shows 0.000 Hz as the default value. Set the rated slip shown on the motor test report. If the motor test report is
not available, do not change this parameter.
■
T1-12: Test Mode Selection
No.
(Hex.)
Name
Description
Default
(Range)
T1-12
(0BDB)
Test Mode Selection
Sets the function to enable Test Mode after Stationary Auto-Tuning. When you can operate the
motor with a light load attached after Stationary Auto-Tuning is complete, enable this parameter.
0
(0, 1)
0 : No
1 : Yes
After Auto-Tuning, the drive automatically sets
E2-02 [Motor Rated Slip]
and
E2-03 [Motor No-Load Current]
when you operate the motor for the first time in Drive Mode.
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...