10.4 A: Initialization Parameters
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
469
10.4 A: Initialization Parameters
◆
A1: Initialization
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
A1-00
(0100)
RUN
Language Selection
Sets the language for the LCD keypad.
Note:
When you use
A1-03 [Initialize Parameters]
to initialize the drive, the drive will
not reset this parameter.
0 : English
1 : Japanese
7 : Chinese
0
(0, 1, 7)
A1-01
(0101)
RUN
Access Level Selection
Sets user access to parameters. The access level controls the parameters shown on the
keypad and which parameters you can set.
0 : Operation Only
1 : User Parameter
2 : Advanced Level
3 : Expert Level
2
(0 - 3)
A1-02
(0102)
Control Method
Selection
Sets the control method for the drive application and the motor.
0 : V/f Control
1 : V/f Control with Encoder
2 : Open Loop Vector
3 : Closed Loop Vector
4 : Advanced Open Loop Vector
2
(0 - 4)
A1-03
(0103)
Initialize Parameters
Sets parameters to default values.
0 : No Initialization
1110 : User Initialization
2220 : 2-Wire Initialization
0
(0 - 2220)
A1-04
(0104)
Password
Enter the correct password set in
A1-05 [Password Setting]
to unlock parameters. You
can view parameter settings. Monitors are locked Enter the password in
A1-04
[Password]
to unlock and change the settings.
0000
(0000 - 9999)
A1-05
(0105)
Password Setting
Set the password to lock parameters and prevent changes to parameter settings. The
following parameters can be changed when the user enters the correct password in
A1-
04 [Password]
that matches the password set in
A1-05
.
0000
(0000 - 9999)
A1-06
(0127)
Application Preset
Sets the drive to operate in selected application conditions.
0 : General-purpose
1 : Crane (Hoist)
2 : Crane (Traveling)
3 : Closed Loop Crane (Hoist)
0
(0 - 3)
A1-11
(111D)
Expert
Firmware Update Lock
Protects the drive firmware. When you enable the protection, you cannot update the
drive firmware.
0 : Disabled
1 : Enabled
0
(0, 1)
A1-12
(1564)
Bluetooth ID
Sets the password necessary to use Bluetooth to control the drive with a smartphone or
tablet.
1915
(0000 - 9999)
A1-13
(156F)
All Function Parameter
Display
Shows and hides applicable parameters.
0 : Disabled
1 : Enabled
1
(0, 1)
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...