11.2 A: Initialization Parameters
572
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
5.
Push
or
to show
[A1-02]
, then push
.
The keypad shows the setting value for
[A1-02]
.
6.
Push
or
to make sure that you can change the setting value.
Push
(Back) until the keypad shows the Parameter Setup Mode screen.
■
A1-05: Password Setting
No.
(Hex.)
Name
Description
Default
(Range)
A1-05
(0105)
Password Setting
Set the password to lock parameters and prevent changes to parameter settings. The following
parameters can be changed when the user enters the correct password in
A1-04 [Password]
that
matches the password set in
A1-05
.
0000
(0000 - 9999)
This parameter can lock these parameter settings:
•
A1-01 [Access Level Selection]
•
A1-02 [Control Method Selection]
•
A1-03 [Initialize Parameters]
•
A1-06 [Application Preset]
•
A2-01 to A2-32 [User Parameter 1 to 32]
Note:
•
Usually, the keypad will not show
A1-05
. To show and set
A1-05
, show
A1-04 [Password]
and then push
and
on the
keypad at the same time.
•
Once
A1-05
is set,
A1-05
is not shown again unless the correct password is entered in
A1-04
. Make sure that you remember the
A1-05
setting value. Contact Yaskawa or your nearest sales representative in case of forgetting the
A1-05
setting value.
•
When
A1-03 = 2220 [2-Wire Initialization]
, the drive is initialized to
A1-05 = 0000
. Be sure to set the password again for applications
that require a password.
•
Change the setting value in
A1-05
to change the password. The new setting value becomes the new password.
•
To lock the parameter again with the same password after unlocking the parameter with the password and changing the parameter,
enter a value other than the password such as
0000
in
A1-04
.
•
If
A1-04
≠
A1-05
, MEMOBUS Communication cannot read or write
A1-05
.
■
A1-06: Application Preset
WARNING!
Sudden Movement Hazard. Check the I/O signals and the external sequences for the drive before you set the
Application Preset function. When you set the Application Preset function (A1-06
≠
0), it changes the I/O terminal functions for
the drive and it can cause equipment to operate unusually. This can cause serious injury or death.
No.
(Hex.)
Name
Description
Default
(Range)
A1-06
(0127)
Application Preset
Sets the drive to operate in selected application conditions.
0
(0 - 3)
The drive software contains the application presets shown below. Set
A1-06
to align with the application to let the
drive automatically set the best parameter settings for the selected application. The drive saves parameters
frequently used for the application in parameters
A2-01 to A2-16 [User Parameters 1 to 16]
for easy configuration
and reference in [User Custom Parameters] in the main menu.
•
Crane (Hoist)
•
Crane (Traveling)
•
Closed Loop Crane (Hoist)
Note:
•
Before you set
A1-06
, make sure that you set
A1-03 = 2220 [Initialize Parameters = 2-Wire Initialization]
to initialize parameters.
•
Make sure that you do Auto-Tuning after you set
A1-06
for a hoist application.
•
It is not possible to change the
A1-06
value. To set an application preset, set
A1-03 = 2220
to initialize parameters, then set this
parameter. If initializing all parameters will cause a problem, do not change the settings.
If you set
A2-33 = 1 [User Parameter Auto Selection = Enabled: Auto Save Recent Parms]
to set parameters to
A2-17 to A2-32 [User
Parameters 17 to 32]
automatically, the drive will reset these parameters when you change the
A1-06
setting.
0 : General-purpose
The drive saves these parameters as user parameters.
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...