686
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
11.8 H: Terminal Functions
H parameters
are used to assign functions to external input and output terminals.
◆
H1: Digital Inputs
H1 Parameters
set the MFDI terminal functions.
■
H1-01 to H1-10 Terminal S1 to S10 Function Selection
The drive has 10 MFDI terminals. Refer to the table for drive default settings and functions.
No.
Name
Default
Function
H1-01
Terminal S1 Function Selection
40
Forward RUN (2-Wire)
H1-02
Terminal S2 Function Selection
41
Reverse RUN (2-Wire)
H1-03
Terminal S3 Function Selection
24
External Fault (NO-Always-Coast)
H1-04
Terminal S4 Function Selection
14
Fault Reset
H1-05
Terminal S5 Function Selection
0
Brake Release Check
H1-06
Terminal S6 Function Selection
3
Multi-Step Speed Reference 1
H1-07
Terminal S7 Function Selection
4
Multi-Step Speed Reference 2
H1-08
Terminal S8 Function Selection
9
Baseblock Command (N.C.)
H1-09
Terminal S9 Function Selection
F
Not Used
H1-10
Terminal S10 Function Selection
F
Not Used
Refer to the following table and use
H1-xx [MFDI Function Select]
to set the function.
Table 11.26 MFDI Setting Values
Setting Value
Function
0
Brake Release Check
2
External Reference 1/2 Selection
3
Multi-Step Speed Reference 1
4
Multi-Step Speed Reference 2
5
Multi-Step Speed Reference 3
6
Jog Reference Selection
7
Accel/Decel Time Selection 1
8
Baseblock Command (N.O.)
9
Baseblock Command (N.C.)
A
Accel/Decel Ramp Hold
B
Overheat Alarm (oH2)
C
Analog Terminal Enable Selection
D
Ignore Speed Fdbk (V/f w/o Enc)
E
ASR Integral Reset
F
Not Used
10
Up Command
11
Down Command
12
Forward Jog
13
Reverse Jog
14
Fault Reset
15
Fast Stop (N.O.)
16
Motor 2 Selection
17
Fast Stop (N.C.)
1A
Accel/Decel Time Selection 2
Setting Value
Function
1B
Programming Lockout
1E
Reference Sample Hold
20 to 2F
External Fault
30
Light-load Accel 1 Enabled
31
Forward Travel Limit (N.O.)
32
Forward Travel Limit (N.C.)
33
Reverse Travel Limit (N.O.)
34
Reverse Travel Limit (N.C.)
35
Impact Stop Enable
36
Light-load Accel 2 Enabled
37
Multi-Step Speed Reference 4
38
Counterweight Selection
39
Motor 3 Selection
3A
Micro Speed Gain1
3B
Micro Speed Gain2
40
Forward RUN (2-Wire)
41
Reverse RUN (2-Wire)
44
Add Offset Frequency 1 (d7-01)
45
Add Offset Frequency 2 (d7-02)
46
Add Offset Frequency 3 (d7-03)
47
Node Setup (CANopen)
60
DC Injection Braking Command
67
Communications Test Mode
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...