184
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
No.
Name
Application Preset (A1-06 Setting)
Crane (Hoist)
(1)
Crane (Traveling)
(2)
Closed Loop Crane (Hoist)
(3)
S1-03
Brake Delay Frequency
3.0 Hz
0.0 Hz
0.0 Hz
S1-04
Brake Delay Time
0.30 s
0.00 s
0.00 s
S1-09
Torque Compensation (FWD)
50%
-
0%
S1-12
Brake Hold Frequency (FWD)
3.0 Hz
0.0 Hz
3.0 Hz
S1-13
Brake Hold Frequency (REV)
3.0 Hz
0.0 Hz
3.0 Hz
S1-14
Slip Prevention Frequency
3.0 Hz
0.0 Hz
0.0 Hz
S1-15
Slip Prevention Time
0.30 s
0.00 s
0.00 s
S1-16
Sequence Fault SE1 Detect Time
0.30 s
0.00 s
0.30 s
S1-17
Sequence Fault SE2 Detect Time
1.00 s
0.00 s
1.00 s
S1-18
Sequence Fault SE3 Detect Time
0.50 s
0.00 s
0.50 s
S1-19
Sequence Fault SE4 Detect Time
0.50 s
0.00 s
0.50 s
S1-54
Brake Sequence Selection
1: Enabled
0: Disabled
1: Enabled
Note:
When
A1-06 [Application Preset] ≠ 0
, the drive shows different parameters on the keypad for different application presets. Set
A1-13
[All Function Parameter Display] = 0
to show all available parameters.
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...