YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
183
3.6
Application Preset
WARNING!
Sudden Movement Hazard. Check the I/O signals and the external sequences for the drive before you set the
Application Preset function. When you set the Application Preset function (A1-06
≠
0), it changes the I/O terminal functions for
the drive and it can cause equipment to operate unusually. This can cause serious injury or death.
The drive software contains the application presets shown below. Set
A1-06 [Application Selection]
to align with
the application to let the drive automatically set the best parameter settings for the selected application.
Set application preset as necessary. The device changes the related parameters based on
A1-06
as shown in
Application
A1-06
Description
Crane (Hoist)
1
The drive automatically sets the parameters for a hoist application.
Note:
Make sure that you do Auto-Tuning after you set
A1-06
for a hoist application.
Crane (Traveling)
2
The drive automatically sets the parameters for a traveling application.
Closed Loop Crane (Hoist)
3
The drive automatically sets the parameters for a closed loop crane (hoist) application.
Note:
After you set
A1-06
for a closed loop crane (hoist) application, make sure that you do Auto-Tuning.
Note:
•
Before you set
A1-06
, make sure that you set
A1-03 = 2220 [Initialize Parameters = 2-Wire Initialization]
to initialize parameters.
•
It is not possible to change the
A1-06
value. To set an application preset, set
A1-03 = 2220
to initialize parameters, then set this
parameter. If initializing all parameters will cause a problem, do not change the settings.
Table 3.7 A1-06 Setting Values and Best Parameter Settings
No.
Name
Application Preset (A1-06 Setting)
Crane (Hoist)
(1)
Crane (Traveling)
(2)
Closed Loop Crane (Hoist)
(3)
A1-02
Control Method Selection
2: Open Loop Vector
0: V/f Control
3: Closed Loop Vector Control
b1-01
Frequency Reference Selection 1
0: Keypad
0: Keypad
0: Keypad
C1-01
Acceleration Time 1
3.0 s
3.0 s
3.0 s
C1-02
Deceleration Time 1
3.0 s
3.0 s
3.0 s
C1-09
Fast Stop Time
2.0 s
2.0 s
2.0 s
d1-01
Reference 1
5.00 Hz
5.00 Hz
5.00 Hz
d1-02
Reference 2
25.00 Hz
25.00 Hz
25.00 Hz
d1-03
Reference 3
50.00 Hz
50.00 Hz
50.00 Hz
E1-03
V/f Pattern Selection
F: Custom
-
F: Custom
F1-05
Encoder 1 Rotation Selection
-
-
1: Pulse B leads in FWD Direction
H1-05
Terminal S5 Function Selection
-
3: Multi-Step Speed Reference 1
-
H1-06
Terminal S6 Function Selection
-
4: Multi-Step Speed Reference 2
-
H1-07
Terminal S7 Function Selection
-
6: Jog Reference Selection
-
H2-01
Term M1-M2 Function Selection
21: Brake Release Command
0: During Run
21: Brake Release Command
H2-02
Term M3-M4 Function Selection
1: Zero Speed
37: During Frequency Output
1: Zero Speed
H3-06
Terminal A3 Function Selection
F: Not Used
F: Not Used
F: Not Used
L2-03
Minimum Baseblock Time
0.1 s
-
0.1 s
L3-04
Stall Prevention during Decel
0: Disabled
0: Disabled
0: Disabled
L4-01
Speed Agree Detection Level
0.0 Hz
-
-
L4-02
Speed Agree Detection Width
0.0 Hz
-
-
L8-05
Input Phase Loss Protection Sel
1: Enabled
1: Enabled
1: Enabled
L8-07
Output Phase Loss Protection Sel
1: Enabled
1: Enabled
1: Enabled
L8-38
Carrier Frequency Reduction
1: Enabled below 6 Hz
1: Enabled below 6 Hz
1: Enabled below 6 Hz
L8-41
High Current Alarm Selection
1: Enabled
1: Enabled
1: Enabled
S1-01
Brake Release Frequency (FWD)
2.0 Hz
0.0 Hz
0.0 Hz
S1-02
Brake Release Frequency (REV)
2.0 Hz
0.0 Hz
0.0 Hz
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...