H5-27: Function 5A Register 3 Selection
No.
(Hex.)
Name
Description
Default
(Range)
H5-27
(158B)
RUN
Function 5A Register 3
Selection
Returns the contents of the specified MEMOBUS/Modbus communications register when
responding to the master device.
0042H (U1-03)
(0000H - FFFFH)
■
H5-28: Function 5A Register 4 Selection
No.
(Hex.)
Name
Description
Default
(Range)
H5-28
(158C)
RUN
Function 5A Register 4
Selection
Returns the contents of the specified MEMOBUS/Modbus communications register when
responding to the master device.
0049H (U1-10)
(0000H - FFFFH)
◆
H7: Virtual MFIO Selection
The virtual I/O function performs the following.
•
Inputs the result of the output from the MFDO terminal to the MFDI terminal without external wiring.
•
Inputs the result of the output from the MFAO terminal to the MFAI terminal without external wiring.
WARNING!
Sudden Movement Hazard. Before you do a test run, make sure that the setting values for virtual input and output
function parameters are correct. Virtual input and output functions can have different default settings and operation than wired
input and output functions. Incorrect function settings can cause serious injury or death.
Figure 11.83 Virtual Analog I/O Functional Block Diagram
Figure 11.84 Virtual Digital I/O Functional Block Diagram
Note:
•
Refer to H1-xx "MFDI Setting Values" for more information on the virtual digital input setting values.
•
Refer to H2-xx "MFDO Setting Values" for more information on the virtual digital output setting values.
•
Refer to H3-xx "MFAI Setting Values" for more information on the virtual analog input setting values.
•
Refer to H4-xx "MFAO Setting Values" for more information on the virtual analog output setting values.
•
You cannot set
20 or 2F [External Fault]
to
H7-01 to H7-04 [Virtual Multi-Function Input 1 to 4]
.
•
If the terminal is not used, set
H7-01 to H7-04 = F
. This does not support the through mode.
•
You cannot use the virtual I/O function selection and the multi-function input for DI-A3 at the same time.
■
H7-00: Virtual MFIO selection
No.
(Hex.)
Name
Description
Default
(Range)
H7-00
(116F)
Expert
Virtual MFIO selection
Sets the function to enable and disable the virtual I/O function. Set this parameter to 1 to operate
the virtual I/O function.
0
(0, 1)
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
H7-01
[Virtual Multi-Function
Input 1]
H7-11
[Virtual Output
1 Delay Time]
H7-10
[Virtual Multi-Function
Output 1]
V/f
CL-V/f
OLV
CLV
AOLV
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...