EZZ023535
20 / 35
SA-64 Alignment Check
No.
(Hex.)
Name
Description
Default Setting
(Range)
SA-64
(1AD5)
RUN
Alignment Check
Sets the detection range for Alignment.
If the deviation between the pulse count when Master
Trigger is input and the pulse count when Slave
Trigger is input is smaller than the total value of
SA-64 and SA-63, multi-function digital output
terminal H2-xx = 55 (In Alignment) turns ON.
100 cnt
(0 - 65535 cnt)
Figure 3.13 In Alignment (Multi-Function Digital Output) with Offset (SA-63 = +3.00 rev and SA-64 = 4096 cnt)
SA-64
SA-64
SA-64
Figure 3.12 In Alignment (Multi-Function Digital Output) without Offset (SA-63 = 0.00 rev and SA-64 = 4096 cnt)
Slave run input
Master Trigger input
Slave Trigger input
In Alignment
SA-64
SA-64
Slave run input
Master Trigger input
Slave Trigger input
In Alignment
SA-63
SA-64
SA-63
SA-64
SA-63
SA-64
SA-63
SA-64