7.4 Replace Cooling Fans and Circulation Fans
406
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
CAUTION!
Burn Hazard. Do not touch a hot drive heatsink. De-energize the drive, wait for a minimum of 15 minutes, then make
sure that the heatsink is cool before you replace the cooling fans. If you touch a hot drive heatsink, it can burn you.
NOTICE:
Use the instructions in this manual to replace the cooling fans. When you do maintenance on the fans, replace all the
fans to increase product life. If you install the fans incorrectly, it can cause damage to the drive.
■
Fan Removal
1.
Remove the drive cover.
CAUTION!
Crush Hazard. Loosen the cover screws. Do not fully remove them. If you fully remove the cover screws,
the terminal cover can fall and cause moderate injury.
2.
Unplug the fan cable from the fan connectors.
A - Fan unit
B - Fan connectors
C - Fan cable
Figure 7.49 Remove the Fan Cable
3.
Loosen the screws that safety the fan unit and slide the slide panel to the left.
Note:
To remove the fan unit, it is only necessary to loosen the screws in position B.
Remove the screws in position A.
A - Screw position A
B - Screw position B
C - Slide panel
Figure 7.50 Slide the Slide Panel
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...