Installation Instructions

 

ELEKTROMAT 
SI 100.10-55,00

 

Model: 10002536 10011

 

 

 
 
 
 
 
 
 
 
 

 

-en- 

 

Status: 26.03.2021

 

 

 

Summary of Contents for 100.10-55,00

Page 1: ...f Installation Instructions ELEKTROMAT SI 100 10 55 00 Model 10002536 10011 en Status 26 03 2021 ...

Page 2: ...2 GfA ELEKTROMATEN GmbH Co KG Wiesenstraße 81 D 40549 Düsseldorf www gfa elektromaten de info gfa elektromaten de ...

Page 3: ...ction 15 9 Limit switch connection 16 10 Emergency manual operation emergency hand crank 17 11 Completion of commissioning testing 19 12 Declaration of incorporation Declaration of conformity 22 Symbols Warning Potential injury or danger to life Warning Danger to life from electric current Note Important information Requirement Required action Schematic representations are based on product example...

Page 4: ...ing of door systems Expert knowledge relevant skills and practical experience are what set apart qualified persons They are capable of safely carrying out the tasks involving installation maintenance and modernisation according to the instructions Safe operation The safe operation of the product can only be ensured if it is used as specified Follow the installation instructions Observe all specifi...

Page 5: ... third parties Warning Danger from improper use of the product Do not let children operate the product unsupervised or use as a toy Warning Danger to life from incorrect installation Work carried out improperly may result in death or severe injury from electrical current or falling parts Allow only competent people to carry out the work Disconnect all cables from the power supply Observe valid reg...

Page 6: ... 18 rpm Supply voltage 3 400 V Operating current 6 50 A Operating frequency 50 Hz Power factor cos φ 0 50 Maximum movement per hour 12 h 1 Hand forces 349 N Class of protection IP 65 Limit switch range maximum revolutions of output shaft hollow shaft 20 Braking torque spring loaded brake 20 Nm Braking voltage 103 130 V DC Rectifier type EGR 230 103 Temperature range 10 40 60 C 1 When using a tempe...

Page 7: ...ocking torque and the approval number of the safety brake are available in the technical data of these instructions Warning Danger of the door dropping If you need to apply more than the permissible force of 390N according to DIN EN 12604 DIN EN 12453 to move the door by emergency manual operation this indicates a stalling on the drive unit or door Releasing the stalling may cause the door to drop...

Page 8: ...even for maximum holding torques or locking torques refer to technical data Connection elements Self locking connection elements with a minimum strength of 800 N mm2 8 8 must be used Utilize the hole diameter to the full Use adequately dimensioned washers for elongated holes BAGAB00002_Z002 BAGAB00003_Z002 3 1 Permissible mounting positions ...

Page 9: ...9 Mounting Two elongated holes are provided for mounting Ⓐ Ⓑ Vertical installation is possible only when an additional torque mount is used Ⓑ ...

Page 10: ...ions of the door manufacturer must also be observed during installation Warning Potential injury or danger to life During installation be sure to use a lifting device that has a sufficient load carrying capacity Thoroughly grease the door shaft BAGAE03003_Z002 Mount the keys BAGAE03004_Z001 ...

Page 11: ...it Version Ⓐ Tighten all connection elements M16 to 175 Nm Install all other connection elements according to the specifications of the door manufacturer Version Ⓑ Raise the pedestal bearing Install the torque mount Do not tighten yet ...

Page 12: ...12 Version Ⓑ Attach the drive unit Version Ⓑ Tighten all connection elements M16 to 175 Nm Install all other connection elements according to the specifications of the door manufacturer ...

Page 13: ...e energised Observe the applicable regulations and standards Make a proper electrical connection Use suitable tools Performing electrical installation Remove the cover Insert the motor plug Insert the limit switch plug BAHAA03_Z001 BAHAC07_Z001 Completing the electrical installation Mount the cable entries and or cable glands ...

Page 14: ...14 6 Limit switch adjustment The adjustment of the final limit positions OPEN and CLOSE is described in the instructions for the door control panel ...

Page 15: ...15 7 Motor connection G1 Rectifier EGR M1 Motor X13 Motor plug Y1 Spring applied brake 8 Alternative motor connection G1 Rectifier EGR M1 Motor X13 Motor plug Y1 Spring applied brake ...

Page 16: ...16 9 Limit switch connection F10 Thermal contact S10 Emergency manual operation X12 DES connection 1 Safety circuit 2 Channel B RS485 3 Ground 4 Channel A RS485 5 Safety circuit 6 Supply voltage ...

Page 17: ...e the emergency manual operation must be carried out against the closed brake Warning Danger of the door dropping If you need to apply more than the permissible force of 390N according to DIN EN 12604 DIN EN 12453 to move the door by emergency manual operation this indicates a stalling on the drive unit or door Releasing the stalling may cause the door to drop Adopt a secure position For drive uni...

Page 18: ...hand crank be used A wrong crank will drop out of the mounting and injure people Only use a crank with the correct diameter The diameter is indicated on the crank handle switch 1 2 m m 1 0 m m BAUA000101_Z001 Plug in the crank and turn until it engages Open or close by turning the crank After use the crank may be attached to the drive unit Attach as illustrated ...

Page 19: ...ng The gearbox stalls Releasing the stalling may cause the door to drop Block the door for pedestrians and vehicles Do not release the stalling Do not use the emergency manual operation Secure the door against dropping Please observe the specifications of the door manufacturer The drive unit needs replacement Please observe the specifications of the door manufacturer Mounting Check all mounting el...

Page 20: ... its equipment The manufacturer s specifications must be observed The brake release for doors without counter balancing may only be used in the CLOSE final limit position Warning Injury or danger to life possible Service life of the brake replacement of the entire brake in the case of Operation with mains supply after 250 000 door cycles Operation with frequency inverter after 1 000 000 door cycle...

Page 21: ...21 Entire drive unit Note Have the drive checked annually by a specialist Shorter inspection interval for frequently used doors Observe the applicable regulations and standards ...

Page 22: ...d complies with the provisions of the above mentioned directives Authorised representative to compile the technical documents is the undersigned Düsseldorf 10 08 2018 Stephan Kleine CEO Signature The following requirements from Appendix I of the Machinery Directive 2006 42 EC are met 1 1 2 1 1 3 1 1 5 1 2 2 1 2 3 1 2 6 1 3 2 1 3 3 1 3 9 1 5 1 1 5 2 1 5 4 1 5 6 1 5 7 1 5 8 1 5 9 1 5 10 1 5 11 1 5 1...

Page 23: ...23 ...

Page 24: ...24 ...