Chapter 36 Nexus Development Interface (NDI)
MPC5602P Microcontroller Reference Manual, Rev. 4
912
Freescale Semiconductor
transitioned through in order for the single-step and/or exit functionality to be performed, even though the
command appears to have no data resource requirement associated with it.
provides bit definitions for the OnCE Command Register.
R/W
GO
EX
RS[0:6]
0
1
2
3
4
5
6
7
8
9
Reset - 10’b1000000010 on assertion of
j_trst_b
or
m_por
, or while in the Test_Logic_Reset state
Figure 36-14. OnCE Command Register
Table 36-11. OnCE Command Register Bit Definitions
Bit(s)
Name
Description
0
R/W
Read/Write Command Bit
The R/W bit specifies the direction of data transfer. The table below describes the options
defined by the R/W bit.
0 – Write the data associated with the command into the register specified by RS[0:6]
1 – Read the data contained in the register specified by RS[0:6]
Note:
The R/W bit generally ignored for read-only or write-only registers, although the PC
FIFO pointer is only guaranteed to be update when R/W=1. In addition, it is ignored for
all bypass operations. When performing writes, most registers are sampled in the
Capture-DR state into a 32-bit shift register, and subsequently shifted out on
j_tdo
during the first 32 clocks of Shift-DR.
1
GO
Go Command Bit
0 – Inactive (no action taken)
1 – Execute instruction in IR
If the GO bit is set, the chip will execute the instruction which resides in the IR register in the
CPUSCR. To execute the instruction, the processor leaves the debug mode, executes the
instruction, and if the EX bit is cleared, returns to the debug mode immediately after executing
the instruction. The processor goes on to normal operation if the EX bit is set, and no other
debug request source is asserted. The GO command is executed only if the operation is a
read/write to CPUSCR or a read/write to “No Register Selected”. Otherwise the GO bit is
ignored.The processor will leave the debug mode after the TAP controller Update-DR state
is entered.
On a GO+NoExit operation, returning to debug mode is treated as a debug event, thus
exceptions such as machine checks and interrupts may take priority and prevent execution
of the intended instruction. Debug firmware should mask these exceptions as appropriate.
The OSR
ERR
bit indicates such an occurrence.
Note that asynchronous interrupts are blocked on a GO+Exit operation until the first
instruction to be executed begins execution.