Chapter 11 System Integration Unit Lite (SIUL)
MPC5602P Microcontroller Reference Manual, Rev. 4
Freescale Semiconductor
249
Table 11-10. PCR[0:71] field descriptions
Field
Description
SMC
Safe Mode Control
This bit supports the overriding of the automatic deactivation of the output buffer of the associated
pad upon entering Safe mode of the device.
0: In Safe mode, output buffer of the pad disabled
1: In Safe mode, output buffer remains functional
APC
Analog Pad Control
This bit enables the usage of the pad as analog input.
0: Analog input path from the pad is gated and cannot be used.
1: Analog input path switch can be enabled by the ADC.
PA[1:0]
Pad Output Assignment
This field selects the function that is allowed to drive the output of a multiplexed pad.The PA field
size can vary from 0 to 2 bits, depending on the number of output functions associated with this
pad.
00: Alternative mode 0: GPIO
01: Alternative mode 1 (see
Chapter 3, “Signal Description
)
Chapter 3, “Signal Description
)
Chapter 3, “Signal Description
)
Note:
The number of bits in the PA bitfield depends of the number of actual alternate functions
provided for each pad. Please see the
MPC5602P Datasheet (MPC5602P)
.
OBE
Output Buffer Enable
This bit enables the output buffer of the pad in case the pad is in GPIO mode.
0: Output buffer of the pad disabled when PA = 00
1: Output buffer of the pad enabled when PA = 00
IBE
Input Buffer Enable
This bit enables the input buffer of the pad.
0: Input buffer of the pad disabled
1: Input buffer of the pad enabled
ODE
Open Drain Output Enable
This bit controls output driver configuration for the pads connected to this signal. Either open drain
or push/pull driver configurations can be selected. This feature applies to output pads only.
0: Open drain enable signal negated for the pad
1: Open drain enable signal asserted for the pad
SRC
Slew Rate Control
0: Slowest configuration
1: Fastest configuration
WPE
Weak Pull Up/Down Enable
This bit controls whether the weak pull up/down devices are enabled/disabled for the pad
connected to this signal.
0: Weak pull device enable signal negated for the pad
1: Weak pull device enable signal asserted for the pad
WPS
Weak Pull Up/Down Select
This bit controls whether weak pull up or weak pull down devices are used for the pads connected
to this signal when weak pull up/down devices are enabled.
0: Pull down enabled
1: Pull up enabled