Service
Request
Number
Description and Action
A13-15x
Description: A non-critical error has been detected, an I/O expansion bus connection failure.
Action: Schedule deferred maintenance. Use “MAP 1230: Linux Platform Error Problem
Resolution” on page 80.
A13-16x
Description: A non-critical error has been detected, an I/O expansion unit not in an operating
state. Action: Schedule deferred maintenance. Use “MAP 1230: Linux Platform Error
Problem Resolution” on page 80.
A13-50x
Description: Recoverable errors on resource indicate a trend toward an unrecoverable error.
However, the resource could not be deconfigured and is still in use. The system is operating
with the potential for an unrecoverable error. Action: If repair is not immediately available,
reboot and the resource will be deconfigured. Then operations can continue in a degraded
mode. To repair use “MAP 1230: Linux Platform Error Problem Resolution” on page 80.
A15-01x
Description: Sensor indicates a fan is turning too slowly. Action: Schedule deferred
maintenance. Use “MAP 1230: Linux Platform Error Problem Resolution” on page 80.
A15-03x
Description: Sensor indicates a voltage outside normal range. Action: Schedule deferred
maintenance. Use “MAP 1230: Linux Platform Error Problem Resolution” on page 80.
A15-05x
Description: Sensor indicates an abnormally high internal temperature. Action: Verify that:
1. The room ambient temperature is within the system operating environment.
2. There is unrestricted air flow around the system.
3. All system covers are closed.
4. There are no fan failures.
If none of these problems exist, then proceed with “MAP 1230: Linux Platform Error Problem
Resolution” on page 80.
A15-07x
Description: Sensor indicates a power supply has failed. Action: Schedule deferred
maintenance. Use “MAP 1230: Linux Platform Error Problem Resolution” on page 80.
A15-09x
Description: Sensor indicates a FRU has failed. Action: Schedule deferred maintenance. Use
“MAP 1230: Linux Platform Error Problem Resolution” on page 80.
A15-11x
Description: Sensor detected a redundant fan failure. Action: Schedule deferred
maintenance. Use “MAP 1230: Linux Platform Error Problem Resolution” on page 80.
A15-12x
Description: Sensor detected redundant power supply failure. Action: Schedule deferred
maintenance. Use “MAP 1230: Linux Platform Error Problem Resolution” on page 80.
A15-13x
Description: Sensor detected a redundant FRU that has failed. Action: Schedule deferred
maintenance. Use “MAP 1230: Linux Platform Error Problem Resolution” on page 80.
A15-14x
Description: Power fault due to unspecified cause. Action: Schedule deferred maintenance.
Use “MAP 1230: Linux Platform Error Problem Resolution” on page 80.
A15-16x
Description: Internal power supply failure. Action: Schedule deferred maintenance. Use
“MAP 1230: Linux Platform Error Problem Resolution” on page 80.
A15-17x
Description: Internal redundant power supply failure. Action: Schedule deferred maintenance.
Use “MAP 1230: Linux Platform Error Problem Resolution” on page 80.
A15-19x
Description: Fan failure. Action: Schedule deferred maintenance. Use “MAP 1230: Linux
Platform Error Problem Resolution” on page 80.
A15-20x
Description: Non-critical cooling problem, loss of redundant fan. Action: Schedule deferred
maintenance. Use “MAP 1230: Linux Platform Error Problem Resolution” on page 80.
538
Eserver
pSeries 630 Model 6C4 and Model 6E4 Service Guide
Summary of Contents for @Server pSeries 630 6C4
Page 1: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver...
Page 2: ......
Page 3: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver...
Page 16: ...xiv Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 18: ...xvi Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 382: ...362 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 440: ...420 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 538: ...System Parts continued 518 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 541: ...Chapter 10 Parts Information 521...
Page 562: ...542 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 568: ...548 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 576: ...556 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 580: ...560 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 616: ...596 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 646: ...626 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 649: ......