Model 6E4 Fan Assembly
1
Model 6E4
8
Processor Cooling Fans Access Cover
2
Outer Side Cover
9
Processor Card Cooling Fan (Fan #2)
3
Service Access Cover
10
Adapter Cooling Fan Assembly (Fan #4)
4
Processor Fan Amber LED
11
Adapter Cooling Fan Assembly (Fan #3)
5
Finger Holes
12
PCI Adapter Fan Amber LED
6
Processor Card Cooling Fan (Fan #1)
13
PCI Adapter Cooling Fan Front Connector
7
Processor Fan Bottom Connector
Hot-Swap Fan Assembly Replacement
Notes:
1. On systems with Linux installed, you might be required to shut down and run AIX diagnostics to verify
the hot-swap fan repair.
2. This note applies only to systems running the AIX operating system.
If a fan assembly is being replaced for a redundant failure, after the service repair action is completed,
ask the customer to check the
crontab
file for any power/cooling warning messages. When a power or
cooling error is encountered, AIX adds an entry to the
crontab
file to
″
wall
″
a warning message every
12 hours, to alert or remind the customer of the problem. Replacing the faulty part does not clear this
crontab
entry, so unless the
crontab
file is edited to remove this entry, the customer continues to be
reminded of the failure despite its having been repaired. Use the
crontab -l
command to read the
crontab
file to determine if an entry exists. Use the
crontab -e
command to edit the file.
Documentation for the AIX operating system is available from the IBM
Eserver
pSeries Information
Center at http://publib16.boulder.ibm.com/pseries/en_US/infocenter/base. Select
AIX documentation
. The
AIX Documentation
CD contains the base set of publications for the operating system, including
system-management and end-user documentation.
The hot-swap fan removal section has a procedure for processor cooling fans and PCI adapter cooling
fans. Select the removal procedure according to the hot-swap fan assembly you are servicing.
To replace your system’s hot-swap cooling fans, do the following:
464
Eserver
pSeries 630 Model 6C4 and Model 6E4 Service Guide
Summary of Contents for @Server pSeries 630 6C4
Page 1: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver...
Page 2: ......
Page 3: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver...
Page 16: ...xiv Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 18: ...xvi Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 382: ...362 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 440: ...420 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 538: ...System Parts continued 518 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 541: ...Chapter 10 Parts Information 521...
Page 562: ...542 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 568: ...548 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 576: ...556 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 580: ...560 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 616: ...596 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 646: ...626 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 649: ......