Service
Request
Number
Description and Action
A03-06x
Description: Mezzanine bus address parity error.
A03-07x
Description: System bus address parity error. Action: Use “MAP 1230: Linux Platform Error
Problem Resolution” on page 80.
A03-08x
Description: Mezzanine bus data parity error. Action: Use “MAP 1230: Linux Platform Error
Problem Resolution” on page 80.
A03-09x
Description: System bus data parity error. Action: Use “MAP 1230: Linux Platform Error
Problem Resolution” on page 80.
A03-10x
Description: Mezzanine bus time-out, transfer or protocol error. Action: Use “MAP 1230:
Linux Platform Error Problem Resolution” on page 80.
A03-11x
Description: System bus time-out error. Action: Use “MAP 1230: Linux Platform Error
Problem Resolution” on page 80.
A03-12x
Description: Error on System bus. Action: Use “MAP 1230: Linux Platform Error Problem
Resolution” on page 80.
A03-13x
Description: I/O Expansion bus parity error. Action: Use “MAP 1230: Linux Platform Error
Problem Resolution” on page 80.
A03-14x
Description: I/O Expansion bus time-out error. Action: Use “MAP 1230: Linux Platform Error
Problem Resolution” on page 80.
A03-15x
Description: I/O Expansion bus connection failure. Action: Use “MAP 1230: Linux Platform
Error Problem Resolution” on page 80.
A03-16x
Description: I/O Expansion unit not in an operating state. Action: Use “MAP 1230: Linux
Platform Error Problem Resolution” on page 80.
A05-00x
Description: Error log analysis indicates an environmental and power warning, but the failure
could not be isolated. Action: Use “MAP 1230: Linux Platform Error Problem Resolution” on
page 80.
A05-01x
Description: Sensor indicates a fan has failed. Action: Use “MAP 1230: Linux Platform Error
Problem Resolution” on page 80.
A05-02x
Description: System shutdown due to a fan failure. Action: Use “MAP 1230: Linux Platform
Error Problem Resolution” on page 80.
A05-03x
Description: Sensor indicates a voltage outside normal range. Action: Use “MAP 1520:
Power” on page 105.
A05-04x
Description: System shutdown due to voltage outside normal range. Action: Use “MAP 1520:
Power” on page 105.
A05-05x
Description: Sensor indicates an abnormally high internal temperature. Action: Verify that:
1. The room ambient temperature is within the system operating environment.
2. There is unrestricted air flow around the system.
3. All system covers are closed.
4. There are no fan failures.
If none of these problems exist, then proceed with “MAP 1230: Linux Platform Error Problem
Resolution” on page 80.
Chapter 11. SRNs for Linux
531
Summary of Contents for @Server pSeries 630 6C4
Page 1: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver...
Page 2: ......
Page 3: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver...
Page 16: ...xiv Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 18: ...xvi Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 382: ...362 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 440: ...420 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 538: ...System Parts continued 518 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 541: ...Chapter 10 Parts Information 521...
Page 562: ...542 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 568: ...548 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 576: ...556 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 580: ...560 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 616: ...596 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 646: ...626 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 649: ......