This option is used by service personnel to dump the SPCN trace data from the system unit or an I/O
subsystem to gather additional debug information.
To dump the SPCN trace data for the processor subsystem (CEC drawer), enter
0
when prompted for
the SPCN drawer number and enter
d0
when prompted for the unit address.
To dump the SPCN trace data for an I/O subsystem, the drawer number must be determined. This can
be done by either:
–
If the system is booted into AIX, use the
″
Identify and System Attention Indicators
″
task to correlate
a drawer and its physical location code (for example, U0.2). Due to the drawer addressing scheme
that is used by the SPCN firmware, the drawer numbers may not match the cabling in a particular
RIO loop. For example, do not assume that the first drawer in the loop will be drawer number 2
(which corresponds to a physical location code of U0.2).
– If the system can be booted to the open firmware prompt, enter
FRU-LER-MENU
at the prompt. Use the
menu to flash the identify indicator on a drawer.
To dump the data for an I/O drawer, enter the drawer number when prompted, then enter
10
for the
unit address as shown in the example below:
Enter the SPCN drawer number:
3
Enter the Unit Address:
10
Note:
It may take up to 5 minutes for the trace data to be dumped to the screen.
The SPCN trace data will be displayed on the screen. An example of this output follows.
Please wait....
***** Power Trace Data Start *****
00000000ffffffffffff0006158800a00
0061574a00000060200353700060210031300060242000000060241040b0006110a004
00006110902000006110208040000000000061102080b0006041000000006d0e385000
006110300000006110902000006040200000006040200010006041000010006d0e3850
1000604100002000000000006d0e385020006041000030006d0e385030006158010000
006154003180006101116000006101116010006158010010007158156a000071100001
000000000000910120000000910120001
***** Power Trace data End *****
(Press Return to Continue)
v
Start SPCN Flash Update
This function is not available on this system.
v
Display Power Subsystem FRU Code Levels
This function is not available on this system.
v
Power Subsystem Code Update via the Power Control Network
This function is not available on this system.
v
LED Indicator Menu
This menu displays the state of the processor subsystem disturbance/system attention LED and the
fault/identify LED on the I/O subsystem(s). Use this menu to toggle the attention/fault LEDs between
identify (blinking) and off. Option 1 is only available when the system is in the error state (the CEC is
powered on and the service processor menus are available). It is not available when the system is in
standby. An example of this menu follows:
Chapter 7. Using the Service Processor
381
Summary of Contents for @Server pSeries 630 6C4
Page 1: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver...
Page 2: ......
Page 3: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver...
Page 16: ...xiv Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 18: ...xvi Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 382: ...362 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 440: ...420 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 538: ...System Parts continued 518 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 541: ...Chapter 10 Parts Information 521...
Page 562: ...542 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 568: ...548 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 576: ...556 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 580: ...560 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 616: ...596 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 646: ...626 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 649: ......