Checkpoint
Description
Action/
Possible Failing FRU
E5E0
Initialize system processor array
1. Check for system firmware updates.
2. Replace the I/O subsystem’s RIO riser
card (location: U0.
dd
-P1.1) specified by
the location code.
3. Replace the I/O subsystem backplane
specified by the location code.
4. Go to “MAP 1540: Problem Isolation
Procedures” on page 124.
E5E1
Reserved
E5E2
Initialization of the hypervisor, phase 1
1. Check for system firmware updates.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 124.
E5E3
Not in quick-restart: load and set up open
firmware code in memory
1. Check for system firmware updates.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 124.
E5E4
Activate slave processors
1. Check for system firmware updates.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 124.
E5E5
Initialize the hypervisor, phase 2
1. Check for system firmware updates.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 124.
E5E6
Set L2 and processor status
1. Check for system firmware updates.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 124.
E5E7
Save I/O hub information for RTAS and
open firmware
1. Check for system firmware updates.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 124.
E5E8
Set up registers
1. Check for system firmware updates.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 124.
E5E9
Reset the quick restart path
1. Check for system firmware updates.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 124.
E5EE
Hang state in main control code
1. Check for system firmware updates.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 124.
E5EF
End of low-level firmware
1. Check for system firmware updates.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 124.
E5FE
Get the system’s licensed memory quantity
from the service processor
1. Remove, then reapply AC power to the
system using the UEPO switch.
2. Verify that the CUoD capacity card is
installed and properly seated.
3. Call service support.
Chapter 4. Checkpoints
199
Summary of Contents for @Server pSeries 630 6C4
Page 1: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver...
Page 2: ......
Page 3: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver...
Page 16: ...xiv Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 18: ...xvi Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 382: ...362 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 440: ...420 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 538: ...System Parts continued 518 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 541: ...Chapter 10 Parts Information 521...
Page 562: ...542 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 568: ...548 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 576: ...556 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 580: ...560 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 616: ...596 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 646: ...626 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 649: ......