Table 4. Firmware Error Codes. (continued)
Error Code Description
Action/
Possible Failing FRU
20EE 000C
Description:
Pointer to the operating system not found in non-volatile storage.
Action:
Values normally found in non-volatile storage that point to the location of an operating
system were not found. This can happen for two reasons, either your installed operating system
does not support storing the values or some event occurred that caused the system to lose
non-volatile storage information (drainage or replacement of the battery). If you are running AIX,
this information can be reconstructed by running the
bootlist
command specifying the device that
the operating system is installed on. Refer to your AIX documentation for the exact syntax and
usage of the
bootlist
command.
To boot the operating system so that the above-mentioned values can be reconstructed, power
off the system and power it on again. This should cause the system to look for the operating
system in the devices contained in the custom boot list or in the default boot list, depending on
the condition of the system. If this is not successful, use the System Management Services
Menus to modify the boot sequence (also known as
boot list
) to include devices that are known
to contain a copy of the operating system. For example, select a hard disk known to have a copy
of the operating system as the first and only device in the boot sequence (boot list) and attempt
to boot again. If the problem persists, replace the CEC backplane.
Location: U0.1-P1.
20EE 000E Unable to execute the open firmware method.
1. Reboot the system.
2. Reflash the system with the latest level of
system firmware.
3. Call service support.
20EE 000F Unable to find the package node.
1. Reboot the system.
2. Reflash the system with the latest level of
system firmware.
3. Call service support.
20EE 0010 Unable to execute the root VPD method.
1. Reboot the system.
2. Reflash the system with the latest level of
system firmware.
3. Call service support.
20EE 0011 Unable to execute the VPD method.
1. Reboot the system.
2. Reflash the system with the latest level of
system firmware.
3. Call service support.
20EE 0012 Unable to execute the mem-dimm-VPD method
1. Reboot the system.
2. Reflash the system with the latest level of
system firmware.
3. Call service support.
20EE 0013 Unable to allocate memory for VPD.
1. Reboot the system.
2. Reflash the system with the latest level of
system firmware.
3. Call service support.
20EE 0014 Unable to allocate memory for location codes.
The system firmware may be corrupted.
Chapter 5. Error Code to FRU Index
233
Summary of Contents for @Server pSeries 630 6C4
Page 1: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver...
Page 2: ......
Page 3: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver...
Page 16: ...xiv Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 18: ...xvi Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 382: ...362 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 440: ...420 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 538: ...System Parts continued 518 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 541: ...Chapter 10 Parts Information 521...
Page 562: ...542 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 568: ...548 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 576: ...556 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 580: ...560 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 616: ...596 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 646: ...626 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 649: ......