Service
Request
Number
Description and Action
A0D-33x
Description: Array of Logic Built in Self Test Error. Action: Use “MAP 1230: Linux Platform
Error Problem Resolution” on page 80.
A0D-34x
Description: Wire Test Error. Action: Use “MAP 1230: Linux Platform Error Problem
Resolution” on page 80.
A0D-35x
Description: Mainstore or Cache IPL Diagnostic Error. Action: Use “MAP 1230: Linux
Platform Error Problem Resolution” on page 80.
A0D-36x
Description: Other IPL Diagnostic Error. Action: Use “MAP 1230: Linux Platform Error
Problem Resolution” on page 80.
A0D-37x
Description: Clock or PLL Error. Action: Use “MAP 1230: Linux Platform Error Problem
Resolution” on page 80.
A0D-38x
Description: Hardware Scan or Initialization Error. Action: Use “MAP 1230: Linux Platform
Error Problem Resolution” on page 80.
A0D-39x
Description: Chip ID Verification Error. Action: Use “MAP 1230: Linux Platform Error Problem
Resolution” on page 80.
A0D-40x
Description: FRU Presence/Detect Error (Mis-Plugged). Action: Use“MAP 1230: Linux
Platform Error Problem Resolution” on page 80.
A10-100
Description: The resource is unavailable due to an error. System is operating in degraded
mode. Action: Use “MAP 1230: Linux Platform Error Problem Resolution” on page 80.
A10-200
Description: The resource was marked failed by the platform. The system is operating in
degraded mode. Action: Schedule maintenance. Use “MAP 1230: Linux Platform Error
Problem Resolution” on page 80.
A10-210
Description: The processor has been deconfigured. The system is operating in degraded
mode. Action: Schedule maintenance. Use “MAP 1230: Linux Platform Error Problem
Resolution” on page 80.
A11-00x
Description: A non-critical error has been detected. Error log analysis indicates an error
detected by the CPU, but the failure could not be isolated. Action: Schedule deferred
maintenance. Use “MAP 1230: Linux Platform Error Problem Resolution” on page 80.
A11-01x
Description: A non-critical error has been detected, a CPU internal error. Action: Schedule
deferred maintenance. Use “MAP 1230: Linux Platform Error Problem Resolution” on
page 80.
A11-02x
Description: A non-critical error has been detected, a CPU internal cache or cache controller
error. Action: Schedule deferred maintenance. Use “MAP 1230: Linux Platform Error
Problem Resolution” on page 80.
A11-03x
Description: A non-critical error has been detected, an external cache parity or multi-bit ECC
error. Action: Schedule deferred maintenance. Use “MAP 1230: Linux Platform Error
Problem Resolution” on page 80.
A11-04x
Description: A non-critical error has been detected, an external cache ECC single-bit error.
Action: Schedule deferred maintenance. Use “MAP 1230: Linux Platform Error Problem
Resolution” on page 80.
A11-05x
Description: A non-critical error has been detected, a system bus time-out error. Action:
Schedule deferred maintenance. Use “MAP 1230: Linux Platform Error Problem Resolution”
on page 80.
A11-06x
Description: A non-critical error has been detected, a time-out error waiting for an I/O device.
Action: Schedule deferred maintenance. Use “MAP 1230: Linux Platform Error Problem
Resolution” on page 80.
A11-07x
Description: A non-critical error has been detected, a system bus parity error. Action:
Schedule deferred maintenance. Use “MAP 1230: Linux Platform Error Problem Resolution”
on page 80.
534
Eserver
pSeries 630 Model 6C4 and Model 6E4 Service Guide
Summary of Contents for @Server pSeries 630 6C4
Page 1: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver...
Page 2: ......
Page 3: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver...
Page 16: ...xiv Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 18: ...xvi Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 382: ...362 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 440: ...420 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 538: ...System Parts continued 518 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 541: ...Chapter 10 Parts Information 521...
Page 562: ...542 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 568: ...548 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 576: ...556 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 580: ...560 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 616: ...596 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 646: ...626 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 649: ......