Table 3. SPCN Error Codes for I/O Subsystems
Error Code Description
Action/
Possible Failing FRU
1nn1 00AC AC loss or brownout detected
Informational message.
1nn1 00EF Remote emergency power off occurred
Informational message.
1nn1 1510 Power supply 1 source failure
1.
Check the input voltage to the power supply.
2. I/O subsystem power supply 1, U0.
dd
-V1.
3. I/O subsystem backplane, U0.
dd
-P1.
1nn1 1511 Power supply 1 fault
1. I/O subsystem power supply 1, U0.
dd
-V1.
2. I/O subsystem backplane, U0.
dd
-P1.
1nn1 1512 Power supply 1 non-power fault
1. I/O subsystem power supply 1, U0.
dd
-V1.
2. I/O subsystem backplane, U0.
dd
-P1.
1nn1 1513 Power supply 1 domain fault
1. I/O subsystem power supply 1, U0.
dd
-V1.
2. I/O subsystem backplane, U0.
dd
-P1.
1nn1 1517 Power supply 1 thermal fault
1. Check for obstructions to the air flow around
the I/O subsystem.
2. I/O subsystem power supply 1, U0.
dd
-V1.
3. I/O subsystem backplane, U0.
dd
-P1.
1nn1 1520 Power supply 2 source failure
1. Check the input voltage to the power supply.
2. I/O subsystem power supply 2, U0.
dd
-V2.
3. I/O subsystem backplane, U0.
dd
-P1.
1nn1 1521 Power supply 2 fault
1. I/O subsystem power supply 2, U0.
dd
-V2.
2. I/O subsystem backplane, U0.
dd
-P1.
1nn1 1522 Power supply 2 non-power fault
1. I/O subsystem power supply 2, U0.
dd
-V2.
2. I/O subsystem backplane, U0.
dd
-P1.
1nn1 1523 Power supply 2 domain fault
1. I/O subsystem power supply 2, U0.
dd
-V2.
2. I/O subsystem backplane, U0.
dd
-P1.
1nn1 1527 Power supply 2 thermal fault
1. Check for obstructions to the air flow around
the I/O subsystem.
2. I/O subsystem power supply 2, U0.
dd
-V2.
3. I/O subsystem backplane, U0.
dd
-P1.
1nn1 1B01 +12 V load fault
1. Replace power supply 1, U0.
dd
-V1.
2. If power supply 2 is present, use power
supply 1 that was removed to replace power
supply 2.
3. I/O subsystem backplane, U0.
dd
-P1.
1nn1 1B02 +5 V load fault
1. Replace power supply 1, U0.
dd
-V1.
2. If power supply 2 is present, use power
supply 1 that was removed to replace power
supply 2.
3. I/O subsystem backplane, U0.
dd
-P1.
Chapter 5. Error Code to FRU Index
223
Summary of Contents for @Server pSeries 630 6C4
Page 1: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver...
Page 2: ......
Page 3: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver...
Page 16: ...xiv Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 18: ...xvi Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 382: ...362 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 440: ...420 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 538: ...System Parts continued 518 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 541: ...Chapter 10 Parts Information 521...
Page 562: ...542 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 568: ...548 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 576: ...556 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 580: ...560 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 616: ...596 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 646: ...626 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 649: ......