Table 5. Service Processor Error Codes. (continued)
Error Code Description
Action/
Possible Failing FRU
4064 00B1 Bus controller failure
1. Check for system firmware updates
2. PCI riser card
Location: U0.1-P2
3. CEC backplane, U0.1-P1
4064 00B3 Processor/VPD problem detected
1. Check for system firmware updates
2. Processor card 1
Location: U0.1-P1-C1
4064 00B4 Processor/VPD problem detected
1. Check for system firmware updates
2. Processor card 2
Location: U0.1-P1-C2
4064 00B7 Insufficient hardware resources were detected to
continue IPL of the system after processor
subsystem testing and initialization was
completed
Go to “MAP 1540: Problem Isolation Procedures”
on page 124.
4064 00D1 Informational message
Informational message
4064 0100 Memory extender 0 on processor card 1
Processor card,
Location: U0.1-P1-C1
4064 0101 Memory extender 2 on processor card 1
Processor card,
Location: U0.1-P1-C1
4064 0130 Memory extender 0 on processor card 2
Processor card,
Location: U0.1-P1-C2
4064 0131 Memory extender 2 on processor card 2
Processor card,
Location: U0.1-P1-C2
4064 0A03 Reboot message (run-time array gard failure) for
processor 0.
Array bit steering, which is a function in the
firmware, may be able to correct this problem
without replacing hardware.
If AIX is available on the system, go to MAP
0235 in the
RS/6000
Eserver
pSeries
Diagnostic Information for Multiple Bus Systems
,
order number SA38-0509.
If Linux is the only operating system on the
system, schedule deferred maintenance with the
customer. When it is possible to reboot the
system, do the following:
1. Using the service processor’s system power
control menu, disable fast mode boot.
(Disabling fast mode automatically enables
slow mode.)
2. Boot the AIX diagnostic CD-ROM.
3. Run diagnostics in problem determination
mode. If no errors are recorded against any
of the processors (devices with a resource
name of proc
x
), array bit steering was
successful and the problem has been
corrected.
If errors are reported against the hardware,
follow the actions for the error code or SRN.
Chapter 5. Error Code to FRU Index
251
Summary of Contents for @Server pSeries 630 6C4
Page 1: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver...
Page 2: ......
Page 3: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver...
Page 16: ...xiv Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 18: ...xvi Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 382: ...362 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 440: ...420 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 538: ...System Parts continued 518 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 541: ...Chapter 10 Parts Information 521...
Page 562: ...542 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 568: ...548 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 576: ...556 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 580: ...560 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 616: ...596 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 646: ...626 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Page 649: ......