Parameter
Values (Range)
Unit
Step
Default
Description
Zro V Hi high Lim
0.00...4.00
xUn
1
0.20
High alarm voltage limit for zero sequence
voltage
Zro V High limit
0.00...4.00
xUn
1
0.05
High warning voltage limit for zero
sequence voltage
Zro V low limit
0.00...4.00
xUn
1
0.00
Low warning voltage limit for zero
sequence voltage
Zro V low low Lim
0.00...4.00
xUn
1
0.00
Low alarm voltage limit for zero sequence
voltage
Zro V deadband
100...100000
1
10000
Deadband configuration value for zero
sequence voltage for integral calculation.
(percentage of difference between min
and max as 0,001 % s)
7.1.10.5
Monitored data
Table 442:
VSMSQI Monitored data
Name
Type
Values (Range)
Unit
Description
NgSeq-kV
FLOAT32
0.00...4.00
xUn
Measured negative
sequence voltage
PsSeq-kV
FLOAT32
0.00...4.00
xUn
Measured positive
sequence voltage
ZroSeq-kV
FLOAT32
0.00...4.00
xUn
Measured zero sequence
voltage
U2_INST
FLOAT32
0.00...4.00
xUn
Negative sequence
voltage amplitude,
instantaneous value
U2_ANGL
FLOAT32
-180.00...180.00
deg
Negative sequence
voltage angle
U2_DB
FLOAT32
0.00...4.00
xUn
Negative sequence
voltage amplitude,
reported value
U2_RANGE
Enum
0=normal
1=high
2=low
3=high-high
4=low-low
Negative sequence
voltage amplitude range
U1_INST
FLOAT32
0.00...4.00
xUn
Positive sequence
voltage amplitude,
instantaneous value
U1_ANGL
FLOAT32
-180.00...180.00
deg
Positive sequence
voltage angle
U1_DB
FLOAT32
0.00...4.00
xUn
Positive sequence
voltage amplitude,
reported value
U1_RANGE
Enum
0=normal
1=high
2=low
3=high-high
4=low-low
Positive sequence
voltage amplitude range
Table continues on next page
Section 7
1MRS757454 D
Measurement functions
378
611 series
Technical Manual
Summary of Contents for Relion 611 Series
Page 1: ... RELION PROTECTION AND CONTROL 611 series Technical Manual ...
Page 2: ......
Page 22: ...16 ...
Page 30: ...24 ...
Page 308: ...302 ...
Page 400: ...394 ...
Page 506: ...500 ...
Page 516: ...510 ...
Page 522: ...516 ...
Page 528: ...522 ...
Page 533: ...527 ...
Page 534: ......
Page 535: ......