A
A.1
Parameter list
A-823
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1213:8
Blocking freq. current setp. filter 2
Min
Standard
Max
Unit
Data type
Effective
1.0
3500.0
7999.0
Hz
Floating Point
immed.
Note:
The current setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1214:8
Bandwidth, current setp. filter 2
Min
Standard
Max
Unit
Data type
Effective
5.0
500.0
7999.0
Hz
Floating Point
immed.
Note:
The current setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1215:8
Numerator, bandwidth current setpoint filter 2
Min
Standard
Max
Unit
Data type
Effective
0.0
0.0
7999.0
Hz
Floating Point
immed.
Note:
The current setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1216:8
Blocking freq. current setp. filter 3
Min
Standard
Max
Unit
Data type
Effective
1.0
3500.0
7999.0
Hz
Floating Point
immed.
Note:
The current setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1217:8
Bandwidth, current setp. filter 3
Min
Standard
Max
Unit
Data type
Effective
5.0
500.0
7999.0
Hz
Floating Point
immed.
Note:
The current setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1218:8
Numerator, bandwidth current setpoint filter 3
Min
Standard
Max
Unit
Data type
Effective
0.0
0.0
7999.0
Hz
Floating Point
immed.
Note:
The current setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1219:8
Blocking freq. current setp. filter 4
Min
Standard
Max
Unit
Data type
Effective
1.0
3500.0
7999.0
Hz
Floating Point
immed.
Note:
The current setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
A Lists
01.99
! 611ue diff !
04.05