0113
Fixed endstop, configuration 1
(–> 3.3)
Min
Standard
Max
Unit
Data type
Effective
0
0
3
–
Unsigned16
immed.
... defines the behavior for fixed end stop/clamping torque not reached.
Bit 0
Behavior for fixed end stop not reached
Bit 0 = 1
Block change is executed
The torque limiting is automatically withdrawn. The block step enable is realized as pro-
grammed in the block.
Bit 0 = 0
Fault 145 is signaled
The axis is braked and stops in front of the programmed target position.
Bit 1
Characteristics for the clamping torque not reached
Bit 1 = 1
Warning 889 is signaled and a block change executed
The block step enable is realized as programmed in the block.
Bit 1 = 0
Warning 889 is signaled
The block step enable changes as programmed in the block only when the clamping torque has
been reached.
Note:
Fault 145 (fixed endstop not reached)
Warning 889 (fixed endstop, axis has not reached the clamping torque)
refer to the index entry ”Travel to endstop”
0114
Fixed endstop, configuration 2
(–> 3.3)
Min
Standard
Max
Unit
Data type
Effective
0
0
1
–
Unsigned16
immed.
... defines how the system can switch into the status ”fixed endstop”.
0
Above following error
The status is automatically reached if the following error exceeds the value set in P0115:8.
1
via input signal
The status is only reached, if it is identified via the input signal ”Fixed endstop sensor”.
Note:
refer to the index entry ”Travel to endstop”
0115:8
Fixed endstop, maximum following error
(–> 3.3)
Min
Standard
Max
Unit
Data type
Effective
0
1000
200000000
MSR
Integer32
immed.
... defines at which following error the ”fixed endstop reached” status is recognized.
The ”fixed endstop reached” status is automatically reached, if the following error exceeds the
theoretically calculated following error by the value entered in P0115:8.
Note:
Prerequisite: P0114 = 0
refer to the index entry ”Travel to endstop”
0116:8
Fixed endstop, monitoring window
(–> 3.3)
Min
Standard
Max
Unit
Data type
Effective
0
100
200000000
MSR
Integer32
immed.
... Defines the monitoring window for the ”fixed endstop reached” status. If the axis exits the
positioning window an appropriate fault is signaled.
Note:
refer to the index entry ”Travel to endstop”