4
01.99
4.4
Commissioning using the display and operator unit
4-130
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
no
yes
Remove write protection (P0651 = 4)
Start to write into FEPROM (P0652 = 1),
wait until the write operation has been completed (P0652 = 0)
Remove write protection (P0651= 1.0.)
Synchronous motor
Induction motor
Enter unlisted motor data
Calculate unlisted motor (set P1082 to 1)
Enter the equivalent
diagram data
End
(cyclic operation)
2
Unlisted
motor
type?
from the previous page
Remove write protection (P0651= 1.0.)
Enter the rating plate data (type)
Calculate unlisted motor
(set P1082 to 1)
Enter the motor code (P1102 = 99)
Calculate the equivalent circuit
diagram data (set P1081 to 1)
Are the equivalent
circuit diagram data
known?
Fig. 4-5
Commissioning using the display and operator unit (Part 3 of 3)
Reader’s note
What is an unlisted motor?
A motor, which is not defined using a motor code number, and is
therefore also not in the Attachment (refer to Chapter A.3.1, A.3.4 and
A.3.5) is classified as an unlisted motor.
The motor can be supplied from Siemens or from another motor
manufacturer.
To commission an unlisted motor, the associated parameters are
required (refer under the index entry ” Unlisted motor – parameters
for...”.