Parameter list
A-783
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
0898
Modulo range master drive
(–> 3.5)
Min
Standard
Max
Unit
Data type
Effective
0
0
100000000
MSR
Unsigned32
PO
... informs the slave drive about the selected modulo range for the master drive.
Note:
The following applies: P0242 (master drive) = P0898 (slave drive)
The value 0 switches-out the modulo correction.
refer under the index entry ”axis couplings”
0899:8
Enter angular incremental encoder direction
(–> 8.1)
Min
Standard
Max
Unit
Data type
Effective
0
0
2
–
Unsigned16
immed.
... defines in which direction the angular incremental encoder interface pulses are permitted.
0
positive and negative direction
1
only the positive direction
2
only the negative direction
Note:
refer to the index entry ”Angular encoder interface”
0900:4
Angular incremental encoder, handwheel evaluation
(–> 8.1)
Min
Standard
Max
Unit
Data type
Effective
1
1
10000
–
Unsigned16
immed.
... defines the factor with which the handwheel pulses are evaluated.
Note:
refer to the index entry ”Angular encoder interface”