6
6.4
Input/output terminals of the control board
6-523
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 6-49
List of output signals, continued
Operating
mode
Signal name, description
PROFIBUS bit
pos
n–set
Fct. No.
Cam switching signal 1
78
–
x
PosZsw.8
Cam switching signal 2
79
–
x
PosZsw.9
For the ”position–related switching signals (cams)” function, the simulated cam signal is output via these
output signals.
Cam switching signal 1
1 signal
Position actual value x
act
cam switching position 1 (P0310)
0 signal
Position actual value x
act
cam switching position 1 (P0310)
Cam switching signal 2
1 signal
Position actual value x
act
cam switching position 2 (P0311)
0 signal
Position actual value x
act
cam switching position 2 (P0311)
P0310
Cam switching signal 1
1 signal
0 signal
Actual position value
Cam switching signal 2
1 signal
0 signal
x
act
P0310
x
act
P0310
x
act
P0311
x
act
P0311
Signal characteristics for a
linear axis
P0311
x
act
[mm]
P0310
Cam switching signal 1
1 signal
0 signal
x
act
[degrees]
Cam switching signal 2
1 signal
0 signal
x
act
P0310 x
act
P0310
x
act
P0311
x
act
P0311
Signal characteristics for a rotary axis
with modulo correction
(from SW 2.4)
P0311
36
0
0
360 0
x
act
P0310
x
act
P0310
Actual position value
x
act
P0311
x
act
P0311
Note:
Only after the axis has been referenced can it be guaranteed that the cam switching signals have a
”true” position reference when they are output.
This is the reason that an external AND logic operation must be established between the output sig-
nal ”reference point set/no reference point set” and the output signals ”cam switching signals 1,2”
(e.g. using an external PLC).
The function ”position–related switching signals (cams)” is described in Chapter 6.2.3.
6 Description of the Functions
01.99
! 611ue diff !
08.01
06.04