5
5.6
Net data (PKW and PZD area)
5-230
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 5-13
Control word (PosStw) for positioning
STW
1
Pos
Anw
Pos
Stw
Reserved
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Activate teach–in (edge) (from SW 4.1)
Set reference point
Tracking operation
Reference cams
Activates coupling (from SW 3.3)
Fixed end stop, sensor (from SW 3.3)
Invert the angular incr. encoder input (from SW 3.5)
Incremental jogging (from SW 4.1)
Note:
The control signals, from the perspective of SIMODRIVE 611 universal are input signals and are
described in Chapter 6.4.3 (also refer to the index entry under Input signal, digital ...).
The percentage value for the velocity override is specified using this
control word.
Over
STW
1
Pos
Anw
Pos
Stw
STW
2
The override normalization is defined using P0883 (override evaluation
PROFIBUS).
Actual override =
P0883
16384
Over
Notice
As the drive cannot rotate with Over = 0 %, then it is important for
PPO types 2, 4 and 5, that a practical value (greater than 0%) is in this
control word.
Negative values are interpreted as maximum value, as this control
word is viewed unsigned.
Control word
PosStw
(pos mode)
Control word
Over
(pos mode)
Normalization of the
override (P0883)
5 Communications via PROFIBUS DP
08.99
08.01