Net data (PKW and PZD area)
5-226
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
The digital outputs at the drive can be controlled, using this control
word from the master side via PROFIBUS.
This terminal must be assigned function number 38 so that an output
terminal can be controlled.
15
0
1
2
3
Bit
1
0
1
1
From int.
P0699 (inverting the
output terminals, refer to Chapter 6.4.5)
Output terminals
P0681
38
P0680 = 38
P0683 = 38
From int.
From int.
From int.
x: Space retainer for drive A or B
DIG
_OUT
P0680 = 38
O0.x:
O1.x:
O2.x:
O3.x:
–1
–1
–1
–1
Fig. 5-11 Control word DIG_OUT (from SW 3.1)
For the ”Spindle positioning” function, the target position is entered via
this control word.
XSP
Data transfer format:
1000
1 degree
Example:
XSP = 145500 ––> 145.5 degrees
Control word
DIG_OUT
(from SW 3.1)
Control word
XSP
(n–set mode)
(from SW 5.1)
5 Communications via PROFIBUS DP
08.99
02.02