3
3.1
Overview when parameterizing
3-88
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
3.1
Overview when parameterizing
You can parameterize ”SIMODRIVE 611 universal” as follows:
Using the display and operator unit on the front panel of
”SIMODRIVE 611 universal”
Using the parameterizing and start–up tool
(SimoCom U) on a PG/PC
– SimoCom U via serial interface (RS232/RS485)
––> refer to Chapter 3.3.3
– SimoCom U via PROFIBUS–DP (CP 5511/CP 5611/CP 5613)
––> refer to Chapter 3.3.4
Online operation
––> the parameter set of a drive is
processed in the RAM of
”SIMODRIVE 611 universal”
Offline mode
––> the parameter set is processed in
a file on the PG/PC
SIMODRIVE 611 universal
FEPROM
(non–volatile
memory)
Display and
operator unit
Drive B
Para–
meter
set
Drive A
Para–
meter
set
RAM
(volatile
memory)
Drive B
Para–
meter
set
Drive A
Para–
meter
set
Save
Switching on
POWER–ON
RESET
Serial
interface
X471)
Serial
interface
(e.g. COM1)
+
P
–
to
display
and
change
parameters
PROFIBUS DP
interface
(e.g. X423)
CP 5511 (PCMCIA card with adapter)
or
CP 5611 CP 5613 (short PCI card)
or
(from SW 3.1)
Parameterizing
and start–up tool
”SimoCom U”
PG/PC
Setup.exe
Fig. 3-1
Overview when parameterizing
General
information
3 Parameterizing the Board
01.99
10.99
08.01